Optical chemical sensors
Project goals
Preparation sensitive elements (films) of optical oxygen sensors with metal complexes immobilized into organic-inorganic polymer ORMOCER. Tests of their oxygen sensitivity and stability in laboratory bioreactor. Preparation sensitive elements of opticalbiosensors with sensitive element that combine optical oxygen sensor with enzyme oxidase. At first sensors of glucose and alcohol will be tested in laboratory bioreactor. After verification of sensitivity and reliability of these sensors, the sensors ofbiogenic amines will be prepared by the identical technique. The application of prepared sensitive films in the packing of poultry meat and evaluation of their utility for control of freshness of packed meat will be done in cooperation with University Maribor.
Keywords
Public support
Provider
Ministry of Education, Youth and Sports
Programme
KONTAKT
Call for proposals
KONTAKT 6 (SMSM2008ME3)
Main participants
—
Contest type
VS - Public tender
Contract ID
1484/2009-32
Alternative language
Project name in Czech
Optické chemické senzory
Annotation in Czech
Příprava citlivých vrstev optických senzorů kyslíku imobilizací kovových komplexů do vrstvy organicko-anorganického polymeru ORMOCER. Testování jejich citlivosti na kyslík a stability v laboratorním bioreaktoru při fermentacích mikroorganismů. Příprava citlivých vrstev optických biosenzoru s citlivou vrstvu kombinující optický kyslíkový senzor s enzymem oxidasou. V laboratorním reaktoru budou testovány nejprve senzory glukosy a alkoholu. Po ověření citlivosti a stability těchto senzorů při fermentacíchbudou stejným postupem připraveny a testovány senzory biogenních aminů. Ve spolupráci s UM provést aplikaci připravených citlivých vrstev na obal drůbežího masa a zhodnocení jejich praktické použitelnosti pro kontrolu čerstvosti baleného masa.
Scientific branches
R&D category
ZV - Basic research
CEP classification - main branch
CB - Analytical chemistry, separation
CEP - secondary branch
GM - Food industry
CEP - another secondary branch
JB - Sensors, detecting elements, measurement and regulation
10406 - Analytical chemistry
20201 - Electrical and electronic engineering
21101 - Food and beverages
Completed project evaluation
Provider evaluation
U - Uspěl podle zadání (s publikovanými či patentovanými výsledky atd.)
Project results evaluation
Novel pH sensitive materials were synthetised for construction of pH optical absorption sensors. The film, which was sensitive to putrescine, was prepared via immobilization of seleable aminoaoxidase on oxygen optode MATINOES.
Solution timeline
Realization period - beginning
Mar 1, 2008
Realization period - end
Dec 31, 2009
Project status
U - Finished project
Latest support payment
Mar 9, 2009
Data delivery to CEP
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data delivery code
CEP10-MSM-ME-U/01:1
Data delivery date
Jun 30, 2010
Finance
Total approved costs
160 thou. CZK
Public financial support
160 thou. CZK
Other public sources
0 thou. CZK
Non public and foreign sources
0 thou. CZK
Basic information
Recognised costs
160 CZK thou.
Public support
160 CZK thou.
100%
Provider
Ministry of Education, Youth and Sports
CEP
CB - Analytical chemistry, separation
Solution period
01. 03. 2008 - 31. 12. 2009