Robotic navigation in catheter ablation for paroxysmal atrial fibrillation: Midterm efficacy and predictors of postablation arrhythmia recurrences
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00023001%3A_____%2F11%3A00002452" target="_blank" >RIV/00023001:_____/11:00002452 - isvavai.cz</a>
Result on the web
<a href="http://dx.doi.org/10.1111/j.1540-8167.2010.01942.x" target="_blank" >http://dx.doi.org/10.1111/j.1540-8167.2010.01942.x</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1111/j.1540-8167.2010.01942.x" target="_blank" >10.1111/j.1540-8167.2010.01942.x</a>
Alternative languages
Result language
angličtina
Original language name
Robotic navigation in catheter ablation for paroxysmal atrial fibrillation: Midterm efficacy and predictors of postablation arrhythmia recurrences
Original language description
Introduction: Remote navigation systems represent a novel strategy for catheter ablation of atrial fibrillation (AF). The goal of this study is to describe a single-center experience with the electromechanical robotic system (Sensei, Hansen Medical) in treatment of patients with paroxysmal AF. Methods: Out of 200 patients who underwent robotically guided ablation for AF between 2007 and 2009 at our institute, 100 patients (29 women, age 56.5 +/- 10 years) had paroxysmal AF refractory to antiarrhythmic drugs. Electroanatomic mapping using NavX system (St. Jude Medical) provided anatomical shell for subsequent circumferential ablation with robotic catheter (Artisan) loaded with a 3.5-mm, open-irrigation, cooled-tip ablation catheter. Results: A mean of 69 radiofrequency current applications (duration 2082 +/- 812 seconds) were delivered to achieve circumferential electrical isolation of pulmonary venous antra. Total procedural time reached 222 +/- 54 minutes. The mean fluoroscopic time w
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
FA - Cardiovascular diseases including cardio-surgery
OECD FORD branch
—
Result continuities
Project
—
Continuities
Z - Vyzkumny zamer (s odkazem do CEZ)
Others
Publication year
2011
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Journal of cardiovascular electrophysiology
ISSN
1045-3873
e-ISSN
—
Volume of the periodical
22
Issue of the periodical within the volume
5
Country of publishing house
GB - UNITED KINGDOM
Number of pages
7
Pages from-to
534-540
UT code for WoS article
000290490000007
EID of the result in the Scopus database
—