Post-heart transplantation outcome of HeartMate II-bridged recipients requiring unplanned concomitant temporary right ventricular mechanical support
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00023001%3A_____%2F15%3A00059253" target="_blank" >RIV/00023001:_____/15:00059253 - isvavai.cz</a>
Result on the web
<a href="http://icvts.oxfordjournals.org/content/20/3/372.full.pdf+html" target="_blank" >http://icvts.oxfordjournals.org/content/20/3/372.full.pdf+html</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1093/icvts/ivu408" target="_blank" >10.1093/icvts/ivu408</a>
Alternative languages
Result language
angličtina
Original language name
Post-heart transplantation outcome of HeartMate II-bridged recipients requiring unplanned concomitant temporary right ventricular mechanical support
Original language description
OBJECTIVES: Second-generation axial-flow left ventricular assist devices (LVADs) have become an established therapy in bridging end-stage heart failure patients to cardiac transplantation. Despite the proven clinical success of these devices, some patients develop right ventricular (RV) failure after LVAD implantation. We sought to determine post-heart transplantation outcomes of HeartMate II (HMII)-bridged patients who developed postimplantation right ventricular failure and received Levitronix CentriMag for RV support in addition to LVAD. RESULTS: Early graft loss was 10.7% in isolated HMII and 25% in HMII + RVAD patients (P = 0.26). There were no observed differences in the rates of primary graft dysfunction (7.3 vs 0%, P = NS), renal failure (16.7 vs 12.5%, P = NS) and stroke (11.1 vs 25%, P = 0.273) between the two groups. Pulmonary artery resistance (odds ratio: 3.286, 95% confidence interval: 1.063-10.157, P = 0.039) was identified as a significant predictor for adverse outcome of mechanically-bridged heart transplant recipients. The 3-year graft survival rate was 86 +/- 5% in isolated HMII and 75 +/- 15% in HMII + RVAD patients, P = 0.326. CONCLUSIONS: Our data demonstrate that heart transplant recipients who required unplanned RV mechanical support after LVAD implantation achieved comparable rates of early graft loss, post-transplant renal failure and stroke rate in comparison with patients bridged with an isolated HeartMate II assist device. Three-year graft survival was equivalent between those two groups. Given the small sample size, further studies involving more patients are needed to support or challenge our conclusions.
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
FA - Cardiovascular diseases including cardio-surgery
OECD FORD branch
—
Result continuities
Project
—
Continuities
N - Vyzkumna aktivita podporovana z neverejnych zdroju
Others
Publication year
2015
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Interactive cardiovascular and thoracic surgery
ISSN
1569-9293
e-ISSN
—
Volume of the periodical
20
Issue of the periodical within the volume
3
Country of publishing house
NL - THE KINGDOM OF THE NETHERLANDS
Number of pages
7
Pages from-to
372-378
UT code for WoS article
000350196400014
EID of the result in the Scopus database
—