Bile duct anastomosis supplied with biodegradable stent in liver transplantation: the initial experience
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00023001%3A_____%2F16%3A00060116" target="_blank" >RIV/00023001:_____/16:00060116 - isvavai.cz</a>
Result on the web
<a href="http://www.sciencedirect.com/science/article/pii/S0041134516306868" target="_blank" >http://www.sciencedirect.com/science/article/pii/S0041134516306868</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.transproceed.2016.09.039" target="_blank" >10.1016/j.transproceed.2016.09.039</a>
Alternative languages
Result language
angličtina
Original language name
Bile duct anastomosis supplied with biodegradable stent in liver transplantation: the initial experience
Original language description
Background. The most common biliary complications after orthotopic liver transplantation are bile leaks, anastomotic and intrahepatic strictures, stones, and ampullary dysfunction. These complications can occur in up to 10% to 30% of liver transplant recipients. Leaks occur early in the posttransplant period; the stricture formation typically graduates over time. Methods. Ten patients underwent transplantation in our preliminary study: 5 were randomized to the group with stent placement and 5 to the control group. We investigated the role of an absorbable biliary stent with the goal of proving patency of duct to-duct biliary anastomosis. The stents are made of machine-knitted polydioxanone monofilaments. Results. Our initial results show that duct-to-duct biliary reconstruction using an absorbable internal stent had good patency in all 5 patients. There were no signs of biliary leakage accompanying the anastomoses in any of the cases, and there was no stone formation observed after liver transplantation. The biliary stent was completely absorbed, with no adverse effects. Conclusions. Based on our initial experience and data, we concluded that biodegradable stents can be successfully and safely used in clinical practice. Further large prospective randomized studies are needed to estimate the efficacy of the bioabsorbable stents.
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
FJ - Surgery including transplantology
OECD FORD branch
—
Result continuities
Project
—
Continuities
N - Vyzkumna aktivita podporovana z neverejnych zdroju
Others
Publication year
2016
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Transplantation proceedings
ISSN
0041-1345
e-ISSN
—
Volume of the periodical
48
Issue of the periodical within the volume
10
Country of publishing house
US - UNITED STATES
Number of pages
5
Pages from-to
3312-3316
UT code for WoS article
000389867000013
EID of the result in the Scopus database
—