Comparison of two modes of long-term ECG monitoring to assess the efficacy of catheter ablation for paroxysmal atrial fibrillation
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00023001%3A_____%2F19%3A00077657" target="_blank" >RIV/00023001:_____/19:00077657 - isvavai.cz</a>
Alternative codes found
RIV/65269705:_____/19:00070821
Result on the web
<a href="http://biomed.papers.upol.cz/pdfs/bio/2019/01/07.pdf" target="_blank" >http://biomed.papers.upol.cz/pdfs/bio/2019/01/07.pdf</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.5507/bp.2018.031" target="_blank" >10.5507/bp.2018.031</a>
Alternative languages
Result language
angličtina
Original language name
Comparison of two modes of long-term ECG monitoring to assess the efficacy of catheter ablation for paroxysmal atrial fibrillation
Original language description
Aims. Optimal ECG monitoring in detecting recurrences of atrial fibrillation (AF) or atrial tachycardia (AT) after catheter ablation has not been well established. The purpose of this prospective study was to compare the utility of daily ECG monitoring with episodic card recorder (ECR) vs. periodic monitoring with episodic loop recorder (ELR) for the detection of post-blanking AF/AT recurrences during early (Months 4-6) and late (Months 7-12) periods after catheter ablation for paroxysmal AF. Methods. The study included 105 consecutive patients, who received ECR for 12 months and were instructed to send at least 2 random ECG recordings daily with extra-recordings during symptoms. The patients were simultaneously monitored for one week with ELR at the end of each period (Months 6 and 12). Results. Thirty-one and 12 patients with AF/AT recurrence were identified by means of ECR and ELR, respectively. In patients with complete and valid data, ELR technology was inferior to ECR by detecting AF/AT in 5 (31%) of 16 and 5 (26%) of 19 patients with arrhythmia identified by ECR in the early and late period, respectively. Overall, ELR had a sensitivity of 8/23 (35%) for detecting AF/AT recurrence.There was no single patient with AF/AT recurrence on ELR that would not be known from ECR monitoring. Only 2 patients with arrhythmia recurrence were completely asymptomatic throughout the study period. Conclusion. Daily ECG monitoring with ECR was better than periodic monitoring with ELR in detecting AF/AT recurrences during the follow-up periods. Entirely asymptomatic patients with AF/AT recurrences were rare
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30201 - Cardiac and Cardiovascular systems
Result continuities
Project
—
Continuities
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Others
Publication year
2019
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Biomedical papers
ISSN
1213-8118
e-ISSN
—
Volume of the periodical
163
Issue of the periodical within the volume
1
Country of publishing house
CZ - CZECH REPUBLIC
Number of pages
7
Pages from-to
54-60
UT code for WoS article
000458362500007
EID of the result in the Scopus database
2-s2.0-85062326184