Intraventricular placement of a spring expander does not attenuate cardiac atrophy of the healthy heart induced by unloading via heterotopic heart transplantation
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00023001%3A_____%2F19%3A00078215" target="_blank" >RIV/00023001:_____/19:00078215 - isvavai.cz</a>
Alternative codes found
RIV/00216208:11130/19:10398478
Result on the web
<a href="http://www.biomed.cas.cz/physiolres/pdf/68/68_567.pdf" target="_blank" >http://www.biomed.cas.cz/physiolres/pdf/68/68_567.pdf</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.33549/physiolres.933936" target="_blank" >10.33549/physiolres.933936</a>
Alternative languages
Result language
angličtina
Original language name
Intraventricular placement of a spring expander does not attenuate cardiac atrophy of the healthy heart induced by unloading via heterotopic heart transplantation
Original language description
An important complication of the prolonged left ventricle assist device support in patients with heart failure is unloading-induced cardiac atrophy which proved resistant to various treatments. Heterotopic heart transplantation (HTx) is the usual experimental model to study this process. We showed previously that implantation of the newly designed intraventricular spring expander can attenuate the atrophy when examined after HTx in the failing heart (derived from animals with established heart failure). The present study aimed to examine if enhanced isovolumic loading achieved by implantation of the expander would attenuate cardiac post-HTx atrophy also in the healthy heart. Cardiac atrophy was assessed as the ratio of the transplanted-to-native heart weight (HW) and its degree was determined on days 7, 14, 21 and 28 after HTx. The transplantation resulted in 32±3, 46±2, 48±3 and 46±3 % HW loss when measured at the four time points; implantation of the expander had no significant effect on these decreases. We conclude that enhanced isovolumic loading achieved by intraventricular implantation of the expander does not attenuate the development of cardiac atrophy after HTx in the healthy heart. This indicates that such an approach does not represent a useful therapeutic measure to attenuate the development of unloading-induced cardiac atrophy.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30201 - Cardiac and Cardiovascular systems
Result continuities
Project
<a href="/en/project/NV16-27420A" target="_blank" >NV16-27420A: New approaches for the prevention of cardiac atrophy: studies in rat model heterotopically transplanted heart</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2019
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Physiological research
ISSN
0862-8408
e-ISSN
—
Volume of the periodical
68
Issue of the periodical within the volume
4
Country of publishing house
CZ - CZECH REPUBLIC
Number of pages
14
Pages from-to
567-580
UT code for WoS article
000483374200005
EID of the result in the Scopus database
2-s2.0-85071710327