Rate, Time Course, and Predictors of Implantable Cardioverter Defibrillator Infections: An Analysis From the SIMPLE Trial
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00023001%3A_____%2F20%3A00080517" target="_blank" >RIV/00023001:_____/20:00080517 - isvavai.cz</a>
Result on the web
<a href="https://reader.elsevier.com/reader/sd/pii/S2589790X20300482?token=0F9FF4AEF44AF95D5CA31B26C12735DF4A4A9AAA42CECC256DDCC414A7A07EAF7244C7F9EC2CB373E6EE67649238DE78" target="_blank" >https://reader.elsevier.com/reader/sd/pii/S2589790X20300482?token=0F9FF4AEF44AF95D5CA31B26C12735DF4A4A9AAA42CECC256DDCC414A7A07EAF7244C7F9EC2CB373E6EE67649238DE78</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.cjco.2020.04.008" target="_blank" >10.1016/j.cjco.2020.04.008</a>
Alternative languages
Result language
angličtina
Original language name
Rate, Time Course, and Predictors of Implantable Cardioverter Defibrillator Infections: An Analysis From the SIMPLE Trial
Original language description
Background: The number of implantable cardioverter defibrillator (ICD) infections is increasing due to an increased number of ICD implants, higher-risk patients, and more frequent replacement procedures, which carry a higher risk of infection. Reducing the morbidity, mortality, and cost of ICD-related infections requires an understanding of the current rate of this complication and its predictors. Methods: The Shock Implant Evaluation Trial (SIMPLE) trial randomized 2500 ICD recipients to defibrillation testing or not. Over an average of 3.1 years, patients were seen every 6 months and examined for evidence of ICD infection, which was defined as requiring device removal and/or intravenous antibiotics. Results: Within 24 months, 21 patients (0.8%) developed infection. Fourteen patients (67%) with infection presented within 30 days, 20 patients by 12 months, and only 1 patient beyond 12 months. Univariate analysis demonstrated that patients with primary electrical disorders (3 patients, P = 0.009) and those with a secondary prevention indication (13 patients, P = 0.0009) were more likely to develop infection. Among the 2.2% of patients who developed an ICD wound hematoma, 10.4% developed an infection. Among the 8.3% of patients requiring an ICD reintervention, 1.9% developed an infection. Conclusions: This cohort of ICD recipients at high-volume centres have a low risk of device-related infection. However; strategies to reduce wound hematoma and the need for ICD reintervention could further reduce the rate of infection. © 2020 Canadian Cardiovascular Society
Czech name
—
Czech description
—
Classification
Type
J<sub>SC</sub> - Article in a specialist periodical, which is included in the SCOPUS database
CEP classification
—
OECD FORD branch
30201 - Cardiac and Cardiovascular systems
Result continuities
Project
—
Continuities
N - Vyzkumna aktivita podporovana z neverejnych zdroju
Others
Publication year
2020
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
CJC Open
ISSN
2589-790X
e-ISSN
—
Volume of the periodical
2
Issue of the periodical within the volume
5
Country of publishing house
US - UNITED STATES
Number of pages
6
Pages from-to
354-359
UT code for WoS article
—
EID of the result in the Scopus database
2-s2.0-85089443353