Comparison of radiation dose and image quality for abdominal CT exams using photon-counting and energy-integrating CT: A self-controlled study including optimized patient positioning
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00023001%3A_____%2F25%3A00085477" target="_blank" >RIV/00023001:_____/25:00085477 - isvavai.cz</a>
Result on the web
<a href="https://www.sciencedirect.com/science/article/pii/S1078817425000501?via%3Dihub" target="_blank" >https://www.sciencedirect.com/science/article/pii/S1078817425000501?via%3Dihub</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.radi.2025.102909" target="_blank" >10.1016/j.radi.2025.102909</a>
Alternative languages
Result language
angličtina
Original language name
Comparison of radiation dose and image quality for abdominal CT exams using photon-counting and energy-integrating CT: A self-controlled study including optimized patient positioning
Original language description
Introduction: Photon-counting detector (PCD) CT represents a major advancement in CT imaging, offering improved image quality and reduced radiation dose compared to traditional energy-integrating detector (EID) CT. This study compared image quality and radiation dose using a self-controlled approach, while evaluating the impact of patient positioning. Methods: This retrospective study analyzed data from 200 patients who underwent abdominal CT scans on both EID (Somatom Definition Flash) and PCD (Naeotom Alpha) scanners. After applying inclusion criteria for proper positioning (within +/- 20 mm) and stable anatomical conditions, 119 patients were included. Radiation doses were assessed using CTDIvol, and image quality was evaluated via CT numbers, noise levels, signal-to-noise ratio (SNR), SNR to dose (SNRD), and contrast-to-noise ratio to dose (CNRD). Results: The study found a median radiation dose reduction of 37 % with PCD CT compared to EID CT (p < 0.05). Image quality assessments revealed significant improvements with PCD CT, including reduced noise levels (up to 31 % in contrast-enhanced organs) and enhanced SNRD (33-51 % increase). CNRD improved by 60-76 %, indicating superior imaging performance of PCD CT. However, 36 % of patients on EID were positioned outside the +/- 20 mm range, which could adversely affect image quality and radiation dose, underscoring the need for more precise patient positioning. Conclusion: This study confirms that PCD CT achieves substantial reductions in radiation dose while enhancing image quality. However, accurate patient positioning is crucial to fully optimize these benefits. Automated tools that ensure proper positioning may be necessary to consistently maintain image quality and reduce radiation exposure. Implications for practice: PCD CT offers improved patient safety and diagnostic imaging. Automated positioning tools are essential to optimize and consistently maintain image quality and minimize radiation exposure. (c) 2025 The College of Radiographers. Published by Elsevier Ltd. All rights are reserved, including those for text and data mining, AI training, and similar technologies.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30224 - Radiology, nuclear medicine and medical imaging
Result continuities
Project
—
Continuities
N - Vyzkumna aktivita podporovana z neverejnych zdroju
Others
Publication year
2025
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Radiography
ISSN
1078-8174
e-ISSN
1532-2831
Volume of the periodical
31
Issue of the periodical within the volume
3
Country of publishing house
GB - UNITED KINGDOM
Number of pages
9
Pages from-to
"art. no. 102909"
UT code for WoS article
001450634500001
EID of the result in the Scopus database
2-s2.0-105000068239