High-contrast X-ray micro-radiography and micro-CT of ex-vivo soft tissue murine organs utilizing ethanol fixation and large area photon-counting detector
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00023272%3A_____%2F16%3AN0000063" target="_blank" >RIV/00023272:_____/16:N0000063 - isvavai.cz</a>
Alternative codes found
RIV/00216208:11120/16:43911951 RIV/68407700:21460/16:00302665 RIV/68407700:21670/16:00302665
Result on the web
<a href="http://dx.doi.org/10.1038/srep30385" target="_blank" >http://dx.doi.org/10.1038/srep30385</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1038/srep30385" target="_blank" >10.1038/srep30385</a>
Alternative languages
Result language
angličtina
Original language name
High-contrast X-ray micro-radiography and micro-CT of ex-vivo soft tissue murine organs utilizing ethanol fixation and large area photon-counting detector
Original language description
Using dedicated contrast agents high-quality X-ray imaging of soft tissue structures with isotropic micrometre resolution has become feasible. This technique is frequently titled as virtual histology as it allows production of slices of tissue without destroying the sample. The use of contrast agents is, however, often an irreversible time-consuming procedure and despite the non-destructive principle of X-ray imaging, the sample is usually no longer usable for other research methods. In this work we present the application of recently developed large-area photon counting detector for high resolution X-ray micro-radiography and micro-tomography of whole ex-vivo ethanol-preserved mouse organs. The photon counting detectors provide dark-current-free quantum-counting operation enabling acquisition of data with virtually unlimited contrast-to-noise ratio (CNR). Thanks to the very high CNR even ethanol-only preserved soft-tissue samples without addition of any contrast agent can be visualized in great detail. As ethanol preservation is one of the standard steps of tissue fixation for histology, the presented method can open a way for widespread use of micro-CT with all its advantages for routine 3D non-destructive soft-tissue visualisation.
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
EG - Zoology
OECD FORD branch
—
Result continuities
Project
<a href="/en/project/TA04011329" target="_blank" >TA04011329: Advanced techniques of X-ray radiography for life sciences and industry</a><br>
Continuities
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Others
Publication year
2016
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Scientific Reports
ISSN
2045-2322
e-ISSN
—
Volume of the periodical
6
Issue of the periodical within the volume
30385
Country of publishing house
GB - UNITED KINGDOM
Number of pages
9
Pages from-to
1-9
UT code for WoS article
000380329600001