Three-Dimensional Transperineal Ultrasound Assessment of the Anal Sphincter Immediately After Vaginal Birth: An Exploratory Study
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00023698%3A_____%2F24%3AN0000005" target="_blank" >RIV/00023698:_____/24:N0000005 - isvavai.cz</a>
Alternative codes found
RIV/00216208:11120/24:43927185
Result on the web
<a href="https://onlinelibrary.wiley.com/doi/10.1002/jum.16490" target="_blank" >https://onlinelibrary.wiley.com/doi/10.1002/jum.16490</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1002/jum.16490" target="_blank" >10.1002/jum.16490</a>
Alternative languages
Result language
angličtina
Original language name
Three-Dimensional Transperineal Ultrasound Assessment of the Anal Sphincter Immediately After Vaginal Birth: An Exploratory Study
Original language description
ObjectivesTo assess the feasibility of acquiring adequate transperineal ultrasound (TPUS) volumes of the anal sphincter (AS) immediately after vaginal birth, the reproducibility of its measurements, and detecting defects therein.MethodsSecondary analysis of TPUS volumes of the AS, acquired immediately after vaginal birth with a transversely oriented convex probe. Two independent experts ranked off-line image quality as "inadequate," "adequate," or "ideal" using the Point-of-Care Ultrasound Image Quality scale. On "adequate" and "ideal" quality volumes, the length of the external AS at 6 and 12 o'clock, and the volume of the external and internal AS were measured. Additionally, volumes were screened for AS defects on tomographic ultrasound imaging. Subsequently, we rated the intra- and interrater agreement on those findings.ResultsOf 183 volumes, 162 were considered "adequate" or of "ideal" quality (88.5%). Reasons for "inadequacy" were shadow artifacts (16/21), poor resolution (3/21), incomplete acquisition (1/21), or aberrant AS morphology (1/21). The intrarater reliability of two-dimensional (2D) and three-dimensional (3D) measurements was excellent, whereas interrater reliability was fair to good for 2D measurements and good for 3D measurements. In those tomographic ultrasound imaging (TUI) sequences including AS defects, the intra- and interrater reliability of the defect measurement were excellent [intraclass correlation coefficient (ICC) = 0.92 (0.80-0.94)] and moderate [ICC = 0.72 (0.63-0.79)]. In this cohort, there were only few (4/48; 8.3%) AS defects. However, grading them was poorly reproducible between experts.ConclusionTPUS of the AS immediately after vaginal birth yields adequate image quality and allows for reproducible measurements. In the few patients with AS defects, there was good agreement on the presence, but it was poor for the extent of defects.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30214 - Obstetrics and gynaecology
Result continuities
Project
—
Continuities
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Others
Publication year
2024
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
JOURNAL OF ULTRASOUND IN MEDICINE
ISSN
0278-4297
e-ISSN
1550-9613
Volume of the periodical
43
Issue of the periodical within the volume
9
Country of publishing house
US - UNITED STATES
Number of pages
9
Pages from-to
1673-1681
UT code for WoS article
001244589700001
EID of the result in the Scopus database
2-s2.0-85195999295