All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

To retrieve, or not to retrieve: System revisions with the Micra transcatheter pacemaker

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00023884%3A_____%2F12%3A00007403" target="_blank" >RIV/00023884:_____/12:00007403 - isvavai.cz</a>

  • Result on the web

    <a href="http://dx.doi.org/10.1016/j.hrthm.2017.07.015" target="_blank" >http://dx.doi.org/10.1016/j.hrthm.2017.07.015</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1016/j.hrthm.2017.07.015" target="_blank" >10.1016/j.hrthm.2017.07.015</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    To retrieve, or not to retrieve: System revisions with the Micra transcatheter pacemaker

  • Original language description

    BACKGROUND: Early experience with leadless pacemakers has shown a low rate of complications. However, little is known about system revision in patients with these devices. OBJECTIVE: The purpose of this study was to describe the system revision experience with the Micra Transcatheter Pacing System (TPS). METHODS: Patients with implants from the Pre-market Micra Transcatheter Pacing Study and the Micra Transcatheter Pacing System Continued Access Study (N = 989) were analyzed and compared with 2667 patients with transvenous pacemakers (TVPs). Revisions included TPS retrieval/explant, repositioning, replacement, or electrical deactivation (with or without prior attempt at retrieval, generally followed by TVP implant) for any reason. Kaplan-Meier revision rates were calculated to account for varying follow-up duration and were compared using a Fine-Gray competing risk model. RESULTS: The actuarial rate for revision at 24 months postimplant was 1.4% for the TPS group (11 revisions in 10 patients), 75% (95% confidence interval 53%-87%; P < .001) lower than the 5.3% for the TVP group (123 revisions in 117 patients). TPS revisions occurred 5-430 days postimplant for elevated pacing thresholds, need for alternate therapy, pacemaker syndrome, and prosthetic valve endocarditis; none were due to device dislodgment or device-related infection. TPS was disabled and left in situ in 7 cases, 3 were retrieved percutaneously (range 9-406 days postimplant), and 1 was surgically removed during aortic valve surgery. CONCLUSION: The overall system revision rate for patients with TPS at 24 months was 1.4%, 75% lower than that for patients with TVPs. TPS was disabled and left in situ in 64% of revisions, and percutaneous retrieval was successful as late as 14 months postimplant.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    30201 - Cardiac and Cardiovascular systems

Result continuities

  • Project

  • Continuities

    N - Vyzkumna aktivita podporovana z neverejnych zdroju

Others

  • Publication year

    2017

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Heart Rhythm

  • ISSN

    1547-5271

  • e-ISSN

  • Volume of the periodical

    14

  • Issue of the periodical within the volume

    12

  • Country of publishing house

    US - UNITED STATES

  • Number of pages

    6

  • Pages from-to

    1801-1806

  • UT code for WoS article

    000417131600012

  • EID of the result in the Scopus database

    2-s2.0-85037145344