Temperature-Controlled Radiofrequency Ablation for Pulmonary Vein Isolation in Patients With Atrial Fibrillation
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00023884%3A_____%2F12%3A00007550" target="_blank" >RIV/00023884:_____/12:00007550 - isvavai.cz</a>
Result on the web
<a href="http://dx.doi.org/10.1016/j.jacc.2017.06.008" target="_blank" >http://dx.doi.org/10.1016/j.jacc.2017.06.008</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.jacc.2017.06.008" target="_blank" >10.1016/j.jacc.2017.06.008</a>
Alternative languages
Result language
angličtina
Original language name
Temperature-Controlled Radiofrequency Ablation for Pulmonary Vein Isolation in Patients With Atrial Fibrillation
Original language description
Background Saline irrigation improved the safety of radiofrequency (RF) ablation, but the thermal feedback for energy titration is absent. Objectives To allow temperature-controlled irrigated ablation, a novel irrigated RF catheter was designed with a diamond-embedded tip (for rapid cooling) and 6 surface thermocouples to reflect tissue temperature. High-resolution electrograms (EGMs) from the split-tip electrode allowed rapid lesion assessment. The authors evaluated the preclinical and clinical performance of this catheter for pulmonary vein (PV) isolation. Methods Using the DiamondTemp (DT) catheter, pigs (n = 6) underwent discrete atrial ablation in a temperature control mode (60°C/50 W) until there was ∼80% EGM amplitude reduction. In a single-center clinical feasibility study, 35 patients underwent PV isolation with the DT catheter (study group); patients were planned for PV remapping after 3 months, regardless of symptomatology. A control group included 35 patients who underwent PV isolation with a standard force-sensing catheter. Results Porcine lesion histology revealed transmurality in 51 of 55 lesions (92.7%). In patients, all PVs were successfully isolated; no char or thrombus formation was observed. Compared with the control group, the study cohort had shorter mean RF application duration (26.3 ± 5.2 min vs. 89.2 ± 27.2 min; p < 0.001), shorter mean fluoroscopic time (11.2 ± 8.5 min vs. 19.5 ± 6.8 min; p < 0.001), and lower acute dormant PV reconduction (0 of 35 vs. 5 of 35; p = 0.024). At 3 months, 23 patients underwent remapping: 39 of 46 PV pairs (84.8%) remained durably isolated in 17 of these patients (73.9%). Conclusions This first-in-human series demonstrated that temperature-controlled irrigated ablation produced rapid, efficient, and durable PV isolation. (ACT DiamondTemp Temperature-Controlled and Contact Sensing RF Ablation Clinical Trial for Atrial Fibrillation [TRAC-AF]; NCT02821351)
Czech name
—
Czech description
—
Classification
Type
J<sub>ost</sub> - Miscellaneous article in a specialist periodical
CEP classification
—
OECD FORD branch
30201 - Cardiac and Cardiovascular systems
Result continuities
Project
—
Continuities
N - Vyzkumna aktivita podporovana z neverejnych zdroju
Others
Publication year
2017
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Journal of the American College of Cardiology
ISSN
0735-1097
e-ISSN
—
Volume of the periodical
70
Issue of the periodical within the volume
5
Country of publishing house
US - UNITED STATES
Number of pages
12
Pages from-to
542-553