Assessment of basic physical and dosimetric parameters of synthetic single-crystal diamond detector and its use in Leksell Gamma Knife and CyberKnife small radiosurgical fields
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00023884%3A_____%2F18%3A00007293" target="_blank" >RIV/00023884:_____/18:00007293 - isvavai.cz</a>
Alternative codes found
RIV/68407700:21340/18:00326380 RIV/00064203:_____/18:10375330
Result on the web
<a href="http://dx.doi.org/10.18869/acadpub.ijrr.16.1.7" target="_blank" >http://dx.doi.org/10.18869/acadpub.ijrr.16.1.7</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.18869/acadpub.ijrr.16.1.7" target="_blank" >10.18869/acadpub.ijrr.16.1.7</a>
Alternative languages
Result language
angličtina
Original language name
Assessment of basic physical and dosimetric parameters of synthetic single-crystal diamond detector and its use in Leksell Gamma Knife and CyberKnife small radiosurgical fields
Original language description
Background: To determine the basic physical and dosimetric properes of a new synthec single-crystal diamond detector and its applicaon for relave small field dosimetry. Materials and Methods: The pre-irradiaon dose required to stabilize detector response, dose rate dependence, photon and electron energy dependence, temperature dependence and angular dependence of MicroDiamond detector response were evaluated. Output factors on Leksell Gamma Knife Perfexion and on CyberKnife were measured to assess detector feasibility in small radiaon field dosimetry. For all measurements, the detector was connected to Unidos electrometer set to 0 voltage. Results: Relave output factors measured on Leksell Gamma Knife Perfexion for 4 mm and 8 mm collimators were in agreement with Monte Carlo reference values from the manufacturer, with deviaons of 0.3% and 2.1%, respecvely. For CyberKnife and fixed circular collimators, the difference in output factor values did not exceed 2% from vendor-supplied values, even for the smallest radiaon field with a diameter of 5 mm. Conclusion: Our results indicate that the MicroDiamond detector is a promising tool for relave small field dosimetry. For output factor measurements on Leksell Gamma Knife Perfexion and CyberKnife, the detector can be used with minimal response correcons applied (correcon factors not larger than 2%).
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
20601 - Medical engineering
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2018
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
International Journal of Radiation Research
ISSN
2322-3243
e-ISSN
—
Volume of the periodical
16
Issue of the periodical within the volume
1
Country of publishing house
IR - IRAN, ISLAMIC REPUBLIC OF
Number of pages
10
Pages from-to
7-16
UT code for WoS article
000427559900002
EID of the result in the Scopus database
2-s2.0-85043272002