Permanent Percutaneous Carotid Artery Filter to Prevent Stroke in Atrial Fibrillation Patients The CAPTURE Trial
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00023884%3A_____%2F19%3A00008242" target="_blank" >RIV/00023884:_____/19:00008242 - isvavai.cz</a>
Result on the web
<a href="http://www.onlinejacc.org/content/74/7/829" target="_blank" >http://www.onlinejacc.org/content/74/7/829</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.jacc.2019.04.035" target="_blank" >10.1016/j.jacc.2019.04.035</a>
Alternative languages
Result language
angličtina
Original language name
Permanent Percutaneous Carotid Artery Filter to Prevent Stroke in Atrial Fibrillation Patients The CAPTURE Trial
Original language description
BACKGROUND Patients with high stroke risk and atrial fibrillation who are unsuitable to oral anticoagulants (OACs) require other stroke prevention strategies. A novel permanent coil filter directly placed into both common carotid arteries (CCAs) was designed to capture emboli >1.4 mm in diameter. OBJECTIVES The multicenter, nonrandomized, first-in-human clinical CAPTURE (Carotid Artery Implant for Trapping Upstream Emboli for Preventing Stroke in Atrial Fibrillation Patients) trial sought to determine the feasibility and safety of bilateral CCA filter placement. METHODS Eligible patients had atrial fibrillation, CHA(2)DS(2)-VASc (Congestive heart failure, Hypertension, Age 75 years, Diabetes, Stroke/transient ischemic attack, Vascular disease, Age 65 to 74 years, Sex category) >= 2, OAC unsuitability, CCA size 4.8 to 9.8 mm, and no carotid stenosis > 30%. Under ultrasound guidance, after direct transcutaneous carotid puncture with a 24-gauge needle, a motorized unit expels the filter to unfurl in the artery. Patients received aspirin/clopidogrel for 3 months, and aspirin thereafter. Primary endpoints were: 1) procedural success-bilateral, properly positioned CCA filters; and 2) 30-day incidence of major adverse events-death, stroke, major bleeding, filter migration, CCA thrombus, or stenosis. Carotid ultrasounds were conducted post-procedure, pre-discharge, at 1 week, and at 1, 3, 6, and 12 months. RESULTS At 3 centers, 25 patients were enrolled: age 71 +/- 9 years, CHA(2)DS(2)-VASc = 4.4 +/- 1.0, prior embolism in 48%. Procedure success was 92% (23 of 25 patients); 1 patient had unilateral deployment. There were no device/procedurerelated major adverse events; minor puncture site hematomas/edema occurred in 5 of 25 (20%). After 6-month mean follow-up, asymptomatic thrombi were detected in 4 patients (1 bilateral, 4 unilateral), adjudicated as captured (n = 3), unclassified (n = 2), or in situ (n = 0). In all patients, the thrombi dissolved with subcutaneous heparin. In 1 patient, 2 device/procedure-unrelated minor strokes occurred. CONCLUSIONS Permanent carotid filter placement for stroke prophylaxis is technically feasible and safe. (Carotid Artery Implant for Trapping Upstream Emboli for Preventing Stroke in Atrial Fibrillation Patients [CAPTURE]; NCT03571789) (C) 2019 The Authors. Published by Elsevier on behalf of the American College of Cardiology Foundation.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30201 - Cardiac and Cardiovascular systems
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2019
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Journal of the American College of Cardiology
ISSN
0735-1097
e-ISSN
—
Volume of the periodical
74
Issue of the periodical within the volume
7
Country of publishing house
US - UNITED STATES
Number of pages
11
Pages from-to
829-839