All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Assessment of Predictors of Left Atrial Volume Response to a Transcatheter InterAtrial Shunt Device (from the REDUCE LAP-HF Trial)

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00023884%3A_____%2F19%3A00008543" target="_blank" >RIV/00023884:_____/19:00008543 - isvavai.cz</a>

  • Result on the web

    <a href="https://www.sciencedirect.com/science/article/abs/pii/S0002914919310586?via%3Dihub" target="_blank" >https://www.sciencedirect.com/science/article/abs/pii/S0002914919310586?via%3Dihub</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1016/j.amjcard.2019.09.019" target="_blank" >10.1016/j.amjcard.2019.09.019</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Assessment of Predictors of Left Atrial Volume Response to a Transcatheter InterAtrial Shunt Device (from the REDUCE LAP-HF Trial)

  • Original language description

    In patients with heart failure and preserved or mildly reduced ejection fractions (EF >= 40%), implantation of an interatrial shunt device (IASD) resulted in heterogenous changes of the left atrial (LA) volume. Baseline characteristics that correlate with a favorable decrease in LA volume are unknown. We hypothesized that a larger ratio of left to right atrial volume at baseline would correlate strongly with LA volume decongestion following IASD implantation. Reduce Elevated LA Pressure in Patients With Heart Failure was a multicenter study of the safety and feasibility of IASD implantation. Sixty-four patients with EF >= 40% underwent device implantation along with baseline conventional echocardiograms, speckle tracking echocardiography, and resting and exercise hemodynamics. Higher LA compliance (-4.2%, p = 0.048) and right atrial reservoir strain (-0.8%, p = 0.005) were independently associated with a percent decrease in the systolic LA volume index from baseline to 6-months. In conclusion, greater LA volume reduction following IASD implantation is associated with higher baseline compliance of the left atrium and higher reservoir strain of the right atrium. (C) 2019 Elsevier Inc. All rights reserved.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    30201 - Cardiac and Cardiovascular systems

Result continuities

  • Project

  • Continuities

    N - Vyzkumna aktivita podporovana z neverejnych zdroju

Others

  • Publication year

    2019

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    American Journal of Cardiology

  • ISSN

    0002-9149

  • e-ISSN

  • Volume of the periodical

    124

  • Issue of the periodical within the volume

    12

  • Country of publishing house

    US - UNITED STATES

  • Number of pages

    6

  • Pages from-to

    1912-1917

  • UT code for WoS article

    000503909900017

  • EID of the result in the Scopus database

    2-s2.0-85074402828