Dose-Lowering in Contrast-Enhanced MRI of the Central Nervous System: A Retrospective, Parallel-Group Comparison Using Gadobenate Dimeglumine
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00023884%3A_____%2F21%3A00009127" target="_blank" >RIV/00023884:_____/21:00009127 - isvavai.cz</a>
Result on the web
<a href="https://onlinelibrary-wiley-com.ezproxy.lib.cas.cz/doi/full/10.1002/jmri.27731" target="_blank" >https://onlinelibrary-wiley-com.ezproxy.lib.cas.cz/doi/full/10.1002/jmri.27731</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1002/jmri.27731" target="_blank" >10.1002/jmri.27731</a>
Alternative languages
Result language
angličtina
Original language name
Dose-Lowering in Contrast-Enhanced MRI of the Central Nervous System: A Retrospective, Parallel-Group Comparison Using Gadobenate Dimeglumine
Original language description
Background Concerns over gadolinium (Gd) retention encourage the use of lower Gd doses. However, lower Gd doses may compromise imaging performance. Higher relaxivity gadobenate may be suited to reduced dose protocols. Purpose To compare 0.05 mmol/kg and 0.1 mmol/kg gadobenate in patients undergoing enhanced MRI of the central nervous system (CNS). Study Type Retrospective, multicenter. Population Three hundred and fifty-two patients receiving 0.05 (n = 181) or 0.1 (n = 171) mmol/kg gadobenate. Field Strength/Sequences 1.5 T and 3.0 T/precontrast and postcontrast T1-weighted spin echo/fast spin echo (SE/FSE) and/or gradient echo/fast field echo (GRE/FFE); precontrast T2-weighted FSE and T2-FLAIR. Assessment Images of patients with extra-axial lesions at 1.5 T or any CNS lesion at 3.0 T were reviewed by three blinded, independent neuroradiologists for qualitative (lesion border delineation, internal morphology visualization, contrast enhancement; scores from 1 = poor to 4 = excellent) and quantitative (lesion-to-brain ratio [LBR], contrast-to-noise ratio [CNR]; SI measurements at regions-of-interest on lesion and normal parenchyma) enhancement measures. Noninferiority of 0.05 mmol/kg gadobenate was determined for each qualitative endpoint if the lower limit of the 95% confidence interval (CI) for the difference in precontrast + postcontrast means was above a noninferiority margin of -0.4. Statistical Tests Student's t-test for comparison of mean qualitative endpoint scores, Wilcoxon signed rank test for comparison of LBR and CNR values; Wilcoxon rank sum test for comparison of SI changes. Tests were significant for P < 0.05. Results The mean change from precontrast to precontrast + postcontrast was significant for all endpoints. Readers 1, 2, and 3 evaluated 304, 225, and 249 lesions for 0.05 mmol/kg gadobenate, and 382, 309, and 298 lesions for 0.1 mmol/kg gadobenate. The lower limit of the 95% CI was above -0.4 for all comparisons. Significantly, higher LBR and CNR was observed with the higher dose. Data Conclusion 0.05 mmol/kg gadobenate was noninferior to 0.1 mmol/kg gadobenate for lesion visualization.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30224 - Radiology, nuclear medicine and medical imaging
Result continuities
Project
—
Continuities
N - Vyzkumna aktivita podporovana z neverejnych zdroju
Others
Publication year
2021
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Journal of magnetic resonance imaging
ISSN
1053-1807
e-ISSN
—
Volume of the periodical
54
Issue of the periodical within the volume
5
Country of publishing house
US - UNITED STATES
Number of pages
16
Pages from-to
1660-1675
UT code for WoS article
000652363000001
EID of the result in the Scopus database
2-s2.0-85106282311