Wireless Communication Between Paired Leadless Pacemakers for Dual-Chamber Synchrony

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00023884%3A_____%2F22%3A00009421" target="_blank" >RIV/00023884:_____/22:00009421 - isvavai.cz</a>

  • Result on the web

    <a href="https://www.ahajournals.org/doi/10.1161/CIRCEP.122.010909" target="_blank" >https://www.ahajournals.org/doi/10.1161/CIRCEP.122.010909</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1161/CIRCEP.122.010909" target="_blank" >10.1161/CIRCEP.122.010909</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Wireless Communication Between Paired Leadless Pacemakers for Dual-Chamber Synchrony

  • Original language description

    Background: Leadless pacemakers (LPs) can mitigate conventional pacemaker complications related to the transvenous leads and subcutaneous pocket surrounding the pulse generator. Although single-chamber leadless pacing has been established, multichamber pacing requires wireless bidirectional communication across multiple LPs to maintain synchrony. This preclinical study demonstrates the chronic performance of implant-to-implant (i2i) communication that achieves synchronous, dual-chamber pacing with 2 LPs. Methods: The i2i communication modality employs subthreshold electrical signals conducted between implanted LPs through the blood and myocardial tissue on a beat-by-beat basis. Right atrial and right ventricular LPs were implanted in 9 ovine subjects. The i2i transmission performance was evaluated 13 weeks after implant. Results: Right atrial and right ventricular LPs were implanted successfully and without complication in 9 ovine subjects. A total of 8715±457 right atrial-to-right ventricular and right ventricular-to-right atrial transmissions were sent per hour, with a success rate of 99.2±0.9%. Of periods with i2i communication failure when DDD pacing was not possible, 97.3±1.8% were resolved within 6 s. Conclusions: For the first time, synchronized, dual-chamber pacing has been demonstrated in a chronic preclinical feasibility study by 2 leadless pacemakers using beat-to-beat, wireless communication, achieving a success rate of 99.2%.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    30201 - Cardiac and Cardiovascular systems

Result continuities

  • Project

  • Continuities

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2022

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Circulation-Arrhythmia and Electrophysiology

  • ISSN

    1941-3149

  • e-ISSN

  • Volume of the periodical

    15

  • Issue of the periodical within the volume

    7

  • Country of publishing house

    US - UNITED STATES

  • Number of pages

    8

  • Pages from-to

    456-463

  • UT code for WoS article

    000827180200004

  • EID of the result in the Scopus database

    2-s2.0-85134855090