All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

High-Voltage Focal Pulsed Field Ablation to Treat Scar-Related Ventricular Tachycardia: The First-in-Human VCAS Trial

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00023884%3A_____%2F25%3A00010184" target="_blank" >RIV/00023884:_____/25:00010184 - isvavai.cz</a>

  • Alternative codes found

    RIV/00023001:_____/25:00086086

  • Result on the web

    <a href="https://www.ahajournals.org/doi/10.1161/CIRCULATIONAHA.125.077025" target="_blank" >https://www.ahajournals.org/doi/10.1161/CIRCULATIONAHA.125.077025</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1161/CIRCULATIONAHA.125.077025" target="_blank" >10.1161/CIRCULATIONAHA.125.077025</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    High-Voltage Focal Pulsed Field Ablation to Treat Scar-Related Ventricular Tachycardia: The First-in-Human VCAS Trial

  • Original language description

    BACKGROUND: Unlike the tremendous progress made in atrial fibrillation ablation, the greatest unmet clinical need is for innovative ablation treatments for scar-related ventricular tachycardia (VT), particularly given the thick, often fibrotic tissue characteristic of the scarred substrate. A focal pulsed field ablation (PFA) catheter with a novel waveform was designed: high voltage to provide tissue penetration and low energy (using short-duration pulses) to avoid tissue overheating. We present the outcomes of VCAS (Ventricular Catheter Ablation Study), a first-in-human study of this PFA catheter to ablate scar-related VT. METHODS: An investigational 8.5F force-sensing PFA catheter was used for scar-VT ablation in ischemic or nonischemic substrates. Pulsed field lesions consisted of 5 applications, each <200 ms, of a high-voltage (>10 kV) monophasic waveform with QRS synchronization. The PFA catheter was localized by electrical impedance-based navigation. A subcohort of patients without previous cardiac surgery underwent epicardial ventricular mapping at baseline and after endocardial PFA to assess for transmurality of endocardial pulsed field lesions. Study end points included procedural efficiency, safety, and effectiveness to final follow-up of 6 months. RESULTS: At 2 centers, 26 patients underwent ablation: 66 +/- 9 years of age, 4% women, left ventricular ejection fraction 32 +/- 10%, VT storm 42%, previous VT ablation 42%. Acute procedural success, achieved in 24 (92%) patients, required 21 (interquartile range, 14-24) lesions per patient with a transpired ablation time of 31 minutes (19-42). Clinical VT was induced in 14 of 16 patients (88%) before ablation and 1 of 16 patients (6%, P<0.001) after ablation. High-density epi-endo voltage mapping was performed in 10 patients [42%]; of the 9 patients undergoing endocardial-only PFA, transmural tissue homogenization was observed in all 9 (100%) patients. Freedom from recurrent VT/ventricular fibrillation (VT/VF) or implantable cardioverter defibrillator shock was 81.8% (95% CI, 67.1-99.8). Regarding VT/VF burden, the incidence rate of postablation VT/VF significantly decreased from baseline to after PFA by 98% (median [IQR], 6 [1-11] versus 0 [0-0], respectively; P<0.001). Primary safety end points within 180 days occurred in 3 of 26 (11.5%) patients: cardiogenic shock, heart failure hospitalization, and retroperitoneal bleed. CONCLUSIONS: In this first-in-human study, the high-voltage PFA catheter efficiently delivered transmural ventricular lesions to treat scar-related VT.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    30201 - Cardiac and Cardiovascular systems

Result continuities

  • Project

  • Continuities

    N - Vyzkumna aktivita podporovana z neverejnych zdroju

Others

  • Publication year

    2025

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Circulation

  • ISSN

    0009-7322

  • e-ISSN

  • Volume of the periodical

    152

  • Issue of the periodical within the volume

    24

  • Country of publishing house

    US - UNITED STATES

  • Number of pages

    14

  • Pages from-to

    1691-1704

  • UT code for WoS article

    001636650200001

  • EID of the result in the Scopus database

    2-s2.0-105025044862