All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Worldwide Chronic Retrieval Experience of Helix-Fixation Leadless Cardiac Pacemakers

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00023884%3A_____%2F25%3A00010195" target="_blank" >RIV/00023884:_____/25:00010195 - isvavai.cz</a>

  • Result on the web

    <a href="https://www.sciencedirect.com/science/article/pii/S0735109724102926?pes=vor&utm_source=clarivate&getft_integrator=clarivate" target="_blank" >https://www.sciencedirect.com/science/article/pii/S0735109724102926?pes=vor&utm_source=clarivate&getft_integrator=clarivate</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1016/j.jacc.2024.10.094" target="_blank" >10.1016/j.jacc.2024.10.094</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Worldwide Chronic Retrieval Experience of Helix-Fixation Leadless Cardiac Pacemakers

  • Original language description

    BACKGROUND: The growing use of leadless pacemaker (LP) technology requires safe and effective solutions for retrieving and removing these devices over the long term. OBJECTIVES This study sought to evaluate retrieval and removal of an active helix-fixation LP studied in worldwide regulatory clinical trials. METHODS Subjects enrolled in the LEADLESS II phase 1 investigational device exemption, LEADLESS Observational, or LEADLESS Japan trials with an attempted LP retrieval at least 6 weeks postimplantation were included. The retrieval success rate was evaluated for all attempted retrievals. Site-reported complications associated with LP retrievals were quantified, with the severity and relationship adjudicated by an independent clinical events committee. RESULTS There were 1,423 successful LP implants and 234 chronic LP retrieval attempts in 233 subjects. The overall retrieval success rate was 87.6% (205 of 234 attempts). The most common reason for failed retrieval (86.2%, 25 of 29 attempts) was inability to access the LP docking button. The mean time from implantation to attempted retrieval was 3.2 years (range 0.2-9.0 years) and did not significantly influence the retrieval success (P 1/4 0.71). The clinical events committee adjudicated 11 complications in 9 subjects as being retrieval related (3.9%, 9 of 233 subjects). CONCLUSIONS The safety and efficacy of chronic LP retrieval of an active helix-fixation device was demonstrated in an international clinical trial setting, with implant durations up to 9 years. (JACC. 2025;85:1111-1120) (c) 2025 The Authors. Published by Elsevier on behalf of the American College of Cardiology Foundation. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    30201 - Cardiac and Cardiovascular systems

Result continuities

  • Project

  • Continuities

    N - Vyzkumna aktivita podporovana z neverejnych zdroju

Others

  • Publication year

    2025

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Journal of the American College of Cardiology

  • ISSN

    0735-1097

  • e-ISSN

  • Volume of the periodical

    85

  • Issue of the periodical within the volume

    11

  • Country of publishing house

    US - UNITED STATES

  • Number of pages

    10

  • Pages from-to

    1111-1120

  • UT code for WoS article

    001486907500001

  • EID of the result in the Scopus database

    2-s2.0-86000432190