All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Pulmonary valve neo-reconstruction using the Ozaki technique in an adapted Ross procedure: case report

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00023884%3A_____%2F25%3A00010218" target="_blank" >RIV/00023884:_____/25:00010218 - isvavai.cz</a>

  • Alternative codes found

    RIV/00064165:_____/25:10500073

  • Result on the web

    <a href="https://academic.oup.com/ehjcr/article/9/7/ytaf291/8168869" target="_blank" >https://academic.oup.com/ehjcr/article/9/7/ytaf291/8168869</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1093/ehjcr/ytaf291" target="_blank" >10.1093/ehjcr/ytaf291</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Pulmonary valve neo-reconstruction using the Ozaki technique in an adapted Ross procedure: case report

  • Original language description

    Aortic valve damage is the most common valvular heart disease in developed countries. The Ross procedure is an alternative to the aortic valve replacement with a prosthesis, providing a longer survival without reoperation and without the need for anticoagulation therapy. The unavailability of homografts for the pulmonary valve replacement is one of the limiting factors for a more common utilization of this therapeutic method.Case summary This case report presents a 35-year-old Caucasian male with a bicuspid aortic valve and severe aortic regurgitation. The patient underwent the Ross procedure with the stabilization of the aortic ring and sinotubular junction. A tubular prosthesis was created from the bovine pericardium, into which three neo-cusp valves were fashioned from autologous pericardium. The new pulmonary conduit was sutured distally to the distal pulmonary trunk and proximally to the right ventricular outflow tract. Four months post-operatively, the follow-up echocardiographic examination documented that the valve in the aortic position had no regurgitation, a maximum velocity of 1.25 m/s, and a peak gradient of 6.25 mmHg. The valve in the pulmonary position showed a trace regurgitation and mean pressure gradient of 13 mmHg.Discussion The combination of the modified Ross procedure with neo-cuspidalization according to Ozaki for a new pulmonary valve thus offers hope for an extended survival without reoperation in paediatric and non-elderly adult patients with an aortic valve dysfunction. This technique is additionally applicable by cardiac surgery centres without access to pulmonary homografts.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    30201 - Cardiac and Cardiovascular systems

Result continuities

  • Project

  • Continuities

    N - Vyzkumna aktivita podporovana z neverejnych zdroju

Others

  • Publication year

    2025

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    European Heart Journal-Case Reports

  • ISSN

    2514-2119

  • e-ISSN

  • Volume of the periodical

    9

  • Issue of the periodical within the volume

    7

  • Country of publishing house

    GB - UNITED KINGDOM

  • Number of pages

    5

  • Pages from-to

  • UT code for WoS article

    001523411300001

  • EID of the result in the Scopus database

    2-s2.0-105010074283