A novel approach to imaging engorged ticks: Micro-CT scanning of Ixodes ricinus fed on blood enriched with gold nanoparticles
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00027162%3A_____%2F21%3AN0000014" target="_blank" >RIV/00027162:_____/21:N0000014 - isvavai.cz</a>
Alternative codes found
RIV/00216305:26220/20:PU137379 RIV/62157124:16810/21:43879655 RIV/62157124:16270/21:43879655
Result on the web
<a href="https://www.sciencedirect.com/science/article/pii/S1877959X20304283?via%3Dihub" target="_blank" >https://www.sciencedirect.com/science/article/pii/S1877959X20304283?via%3Dihub</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.ttbdis.2020.101559" target="_blank" >10.1016/j.ttbdis.2020.101559</a>
Alternative languages
Result language
angličtina
Original language name
A novel approach to imaging engorged ticks: Micro-CT scanning of Ixodes ricinus fed on blood enriched with gold nanoparticles
Original language description
Micro-computed tomography (micro-CT) is an exceptional imaging modality which is limited in visualizing soft biological tissues that need pre-examination contrasting steps, which can cause serious deformation to sizeable specimens like engorged ticks. The aim of this study was to develop a new technique to bypass these limitations and allow the imaging of fed ticks in their natural state. To accomplish this, adult Ixodes ricinus females were allowed to engorge in vitro on blood supplemented with PEGylated gold nanoparticles (PEG-AuNPs). In total, 73/120 females divided into 6 groups engorged on blood enriched with 0.07-2.16 mg PEG-AuNPs per ml of blood. No toxic effect was observed for any of the tested groups compared to the control group, in which 12/20 females engorged on clear blood. The ticks were scanned on a Bruker micro-CT SkyScan 1276. The mean radiodensity of the examined ticks exceeded 0 Hounsfield Units only in the case of the two groups with the highest concentration. The best contrast was observed in ticks engorged on blood with the highest tested concentration of 2.16 mg/mL PEG-AuNPs. In these ticks, the midgut and rectal sac were clearly visible. Also, the midgut lumen volume was computed from segmented image data. The reduction in midgut volume was documented during the egg development process. According to this pilot study, micro-CT of ticks engorged on blood supplemented with contrasting agents in vitro may reveal additional information regarding the engorged ticks' anatomy.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30310 - Parasitology
Result continuities
Project
<a href="/en/project/EF15_003%2F0000495" target="_blank" >EF15_003/0000495: FIT (Pharmacology, Immunotherapy, nanoToxicology)</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2021
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Ticks and Tick-borne Diseases
ISSN
1877-959X
e-ISSN
1877-9603
Volume of the periodical
12
Issue of the periodical within the volume
1
Country of publishing house
DE - GERMANY
Number of pages
6
Pages from-to
"101559"
UT code for WoS article
000599848100013
EID of the result in the Scopus database
2-s2.0-85094621340