Treatment of High Flow Arteriovenous Fistulas after Successful Renal Transplant Using a Simple Precision Banding Technique
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00064165%3A_____%2F16%3A10325179" target="_blank" >RIV/00064165:_____/16:10325179 - isvavai.cz</a>
Alternative codes found
RIV/00216208:11110/16:10325179
Result on the web
<a href="http://dx.doi.org/10.1016/j.avsg.2015.08.012" target="_blank" >http://dx.doi.org/10.1016/j.avsg.2015.08.012</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.avsg.2015.08.012" target="_blank" >10.1016/j.avsg.2015.08.012</a>
Alternative languages
Result language
angličtina
Original language name
Treatment of High Flow Arteriovenous Fistulas after Successful Renal Transplant Using a Simple Precision Banding Technique
Original language description
Background: Observation versus ligation of a functional arteriovenous fistula (AVF) after successful renal transplantation (SRT) has been a controversial topic of debate. Congestive heart failure and pulmonary hypertension are common in dialysis patients, and more frequent when vascular access flow is excessive. Renal transplant failure may occur in up to 34% of patients after 5 years, therefore maintaining a moderate flow AVF appears warranted. We review SRT patients with high flow-AVFs (HF-AVF) and clinical signs of heart failure where a modified precision banding procedure was used for access flow reduction. Methods: Patients referred for HF-AVF evaluation after SRT were identified and records reviewed retrospectively. In addition to recording clinical signs of heart failure, each patient had ultrasound AVF flow measurement before and after temporary AVF occlusion of the access by digital compression. Pulse rate and the presence or absence of a cardiac murmur was noted before and after AVF compression. Adequacy of access flow restriction was evaluated intraoperatively using ultrasound flow measurements, adjusting the banding diameter in 0.5 mm increments to achieve the targeted AVF flow. Conclusions: Patients with successful renal transplants and HF-AVFs had resolution of heart failure findings and maintenance of access patency using a modified precision banding procedure. Flow reduction in symptomatic renal transplant patients with elevated access flow is recommended. Further study is warranted to substantiate these recommendations and clarify the appropriate thresholds for such interventions.
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
FA - Cardiovascular diseases including cardio-surgery
OECD FORD branch
—
Result continuities
Project
—
Continuities
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Others
Publication year
2016
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Annals of Vascular Surgery
ISSN
0890-5096
e-ISSN
—
Volume of the periodical
31
Issue of the periodical within the volume
February
Country of publishing house
US - UNITED STATES
Number of pages
6
Pages from-to
85-90
UT code for WoS article
000370211300012
EID of the result in the Scopus database
2-s2.0-84966505787