All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Treatment of High Flow Arteriovenous Fistulas after Successful Renal Transplant Using a Simple Precision Banding Technique

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00064165%3A_____%2F16%3A10325179" target="_blank" >RIV/00064165:_____/16:10325179 - isvavai.cz</a>

  • Alternative codes found

    RIV/00216208:11110/16:10325179

  • Result on the web

    <a href="http://dx.doi.org/10.1016/j.avsg.2015.08.012" target="_blank" >http://dx.doi.org/10.1016/j.avsg.2015.08.012</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1016/j.avsg.2015.08.012" target="_blank" >10.1016/j.avsg.2015.08.012</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Treatment of High Flow Arteriovenous Fistulas after Successful Renal Transplant Using a Simple Precision Banding Technique

  • Original language description

    Background: Observation versus ligation of a functional arteriovenous fistula (AVF) after successful renal transplantation (SRT) has been a controversial topic of debate. Congestive heart failure and pulmonary hypertension are common in dialysis patients, and more frequent when vascular access flow is excessive. Renal transplant failure may occur in up to 34% of patients after 5 years, therefore maintaining a moderate flow AVF appears warranted. We review SRT patients with high flow-AVFs (HF-AVF) and clinical signs of heart failure where a modified precision banding procedure was used for access flow reduction. Methods: Patients referred for HF-AVF evaluation after SRT were identified and records reviewed retrospectively. In addition to recording clinical signs of heart failure, each patient had ultrasound AVF flow measurement before and after temporary AVF occlusion of the access by digital compression. Pulse rate and the presence or absence of a cardiac murmur was noted before and after AVF compression. Adequacy of access flow restriction was evaluated intraoperatively using ultrasound flow measurements, adjusting the banding diameter in 0.5 mm increments to achieve the targeted AVF flow. Conclusions: Patients with successful renal transplants and HF-AVFs had resolution of heart failure findings and maintenance of access patency using a modified precision banding procedure. Flow reduction in symptomatic renal transplant patients with elevated access flow is recommended. Further study is warranted to substantiate these recommendations and clarify the appropriate thresholds for such interventions.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)

  • CEP classification

    FA - Cardiovascular diseases including cardio-surgery

  • OECD FORD branch

Result continuities

  • Project

  • Continuities

    V - Vyzkumna aktivita podporovana z jinych verejnych zdroju

Others

  • Publication year

    2016

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Annals of Vascular Surgery

  • ISSN

    0890-5096

  • e-ISSN

  • Volume of the periodical

    31

  • Issue of the periodical within the volume

    February

  • Country of publishing house

    US - UNITED STATES

  • Number of pages

    6

  • Pages from-to

    85-90

  • UT code for WoS article

    000370211300012

  • EID of the result in the Scopus database

    2-s2.0-84966505787