Implantation of cardiac electronic devices in active COVID-19 patients: Results from an international survey
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00064165%3A_____%2F22%3A10440199" target="_blank" >RIV/00064165:_____/22:10440199 - isvavai.cz</a>
Alternative codes found
RIV/00216208:11110/22:10440199
Result on the web
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=oBR8vdIxPV" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=oBR8vdIxPV</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.hrthm.2021.10.020" target="_blank" >10.1016/j.hrthm.2021.10.020</a>
Alternative languages
Result language
angličtina
Original language name
Implantation of cardiac electronic devices in active COVID-19 patients: Results from an international survey
Original language description
BACKGROUND: Cardiac implantable electronic device (CIED) implantation rates as well as the clinical and procedural characteristics and outcomes in patients with known active coronavirus disease 2019 (COVID-19) are unknown. OBJECTIVE: The purpose of this study was to gather information regarding CIED procedures during active COVID-19, performed with personal protective equipment, based on an international survey. METHODS: Fifty-three centers from 13 countries across 4 continents provided information on 166 patients with known active COVID-19 who underwent a CIED procedure. RESULTS: The CIED procedure rate in 133,655 hospitalized COVID-19 patients ranged from 0 to 16.2 per 1000 patients (P <.001). Most devices were implanted due to high-degree/complete atrioventricular block (112 [67.5%]) or sick sinus syndrome (31 [18.7%]). Of the 166 patients in the study survey, the 30-day complication rate was 13.9% and the 180-day mortality rate was 9.6%. One patient had a fatal outcome as a direct result of the procedure. Differences in patient and procedural characteristics and outcomes were found between Europe and North America. An older population (76.6 vs 66 years; P <.001) with a nonsignificant higher complication rate (16.5% vs 7.7%; P = .2) was observed in Europe vs North America, whereas higher rates of critically ill patients (33.3% vs 3.3%; P <.001) and mortality (26.9% vs 5%; P = .002) were observed in North America vs Europe. CONCLUSION: CIED procedure rates during known active COVID-19 disease varied greatly, from 0 to 16.2 per 1000 hospitalized COVID-19 patients worldwide. Patients with active COVID-19 infection who underwent CIED implantation had high complication and mortality rates. Operators should take these risks into consideration before proceeding with CIED implantation in active COVID-19 patients.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30201 - Cardiac and Cardiovascular systems
Result continuities
Project
—
Continuities
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Others
Publication year
2022
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Heart Rhythm
ISSN
1547-5271
e-ISSN
1556-3871
Volume of the periodical
19
Issue of the periodical within the volume
2
Country of publishing house
US - UNITED STATES
Number of pages
11
Pages from-to
206-216
UT code for WoS article
000749526600006
EID of the result in the Scopus database
2-s2.0-85120168356