Ultrasound-guided injection of the achilles paratenon: A cadaveric investigation
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00064165%3A_____%2F24%3A10475184" target="_blank" >RIV/00064165:_____/24:10475184 - isvavai.cz</a>
Alternative codes found
RIV/00216208:11110/24:10475184 RIV/00216208:11130/24:10475184 RIV/00064203:_____/24:10475184
Result on the web
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=0-.mTVxy2r" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=0-.mTVxy2r</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.fas.2024.01.005" target="_blank" >10.1016/j.fas.2024.01.005</a>
Alternative languages
Result language
angličtina
Original language name
Ultrasound-guided injection of the achilles paratenon: A cadaveric investigation
Original language description
BACKGROUND: Injections around the Achilles tendon (AT) are commonly performed in clinical practice to manage non-insertional Achilles tendinopathy, but the presence/distribution of the injectate with relation to its sheath has not been assessed specifically. Accordingly, the aim of this cadaveric investigation was to demonstrate the feasibility of Achilles paratenon injection under ultrasound guidance - by confirming the exact needle positioning as well as the dye distribution inside the paratenon lumen. METHODS: A descriptive laboratory study with three human cadaveric specimens (one fresh cadaver and two cadavers embalmed using the Fix for Life (F4L) method) was performed in a tertiary-care academic institution. The interventional technique and the related anatomical findings were illustrated. During the injection, the needle was advanced inside the Achilles paratenon under ultrasound guidance i.e. in-plane medial-to-lateral approach. With the objective to confirm its correct placement, the needle was kept in situ on the right AT of the fresh cadaver. Likewise, to demonstrate the location of the dye inside the lumen of Achilles paratenon, the other five ATs - four on the embalmed cadavers and one on the fresh cadaver - were injected with 5 mL of green color dye. After removal of the needle, a layer-by-layer anatomical dissection was performed on all three cadavers. RESULTS: On the right AT of the fresh cadaver, the position of the needle's tip within the Achilles paratenon was confirmed. Accurate placement of the dye inside the paratenon lumen was confirmed in four (80%) ATs, one of the fresh and three of the embalmed cadavers. No spread inside the crural fascia compartment or between the AT and the Kager's fat pad was observed. Herewith, unintentional spilling of the dye within the superficial soft tissues of the posterior leg was reported in the left AT of one of the two embalmed cadavers (20%). CONCLUSIONS: Ultrasound-guided injection using the in-plane, medial-to-lateral approach can accurately target the lumen of Achilles paratenon.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30106 - Anatomy and morphology (plant science to be 1.6)
Result continuities
Project
—
Continuities
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Others
Publication year
2024
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Foot and Ankle Surgery
ISSN
1268-7731
e-ISSN
1460-9584
Volume of the periodical
30
Issue of the periodical within the volume
4
Country of publishing house
GB - UNITED KINGDOM
Number of pages
6
Pages from-to
313-318
UT code for WoS article
001294475900001
EID of the result in the Scopus database
2-s2.0-85184064578