What is cardiogenic shock? New clinical criteria urgently needed
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00064165%3A_____%2F24%3A10481085" target="_blank" >RIV/00064165:_____/24:10481085 - isvavai.cz</a>
Alternative codes found
RIV/00216208:11110/24:10481085 RIV/00216208:11130/24:10481085 RIV/00064203:_____/24:10481085
Result on the web
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=OGDRQ49.M1" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=OGDRQ49.M1</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1097/MCC.0000000000001172" target="_blank" >10.1097/MCC.0000000000001172</a>
Alternative languages
Result language
angličtina
Original language name
What is cardiogenic shock? New clinical criteria urgently needed
Original language description
PURPOSE OF REVIEW: Cardiogenic shock is a clinical syndrome with different causes and a complex pathophysiology. Recent evidence from clinical trials evokes the urgent need for redefining clinical diagnostic criteria to be compliant with the definition of cardiogenic shock and current diagnostic methods. RECENT FINDINGS: Conflicting results from randomized clinical trials investigating mechanical circulatory support in patients with cardiogenic shock have elicited several extremely important questions. At minimum, it is questionable whether survivors of cardiac arrest should be included in trials focused on cardiogenic shock. Moreover, considering the wide availability of ultrasound and hemodynamic monitors capable of arterial pressure analysis, the current clinical diagnostic criteria based on the presence of hypotension and hypoperfusion have become insufficient. As such, new clinical criteria for the diagnosis of cardiogenic shock should include evidence of low cardiac output and appropriate ventricular filling pressure. SUMMARY: Clinical diagnostic criteria for cardiogenic shock should be revised to better define cardiac pump failure as a primary cause of hemodynamic compromise.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30201 - Cardiac and Cardiovascular systems
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2024
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Current Opinion in Critical Care
ISSN
1070-5295
e-ISSN
1531-7072
Volume of the periodical
30
Issue of the periodical within the volume
4
Country of publishing house
US - UNITED STATES
Number of pages
5
Pages from-to
319-323
UT code for WoS article
001262286400007
EID of the result in the Scopus database
2-s2.0-85197769065