The impact of modifiable factors on image quality of prostate magnetic resonance imaging and PI-RADS scores
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00064165%3A_____%2F25%3A10495663" target="_blank" >RIV/00064165:_____/25:10495663 - isvavai.cz</a>
Alternative codes found
RIV/00216208:11110/25:10495663 RIV/00216208:11120/25:43928274 RIV/00216208:11130/25:10495663 RIV/00064203:_____/25:10495663
Result on the web
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=6iRksGZ4Ta" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=6iRksGZ4Ta</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.21037/qims-24-1776" target="_blank" >10.21037/qims-24-1776</a>
Alternative languages
Result language
angličtina
Original language name
The impact of modifiable factors on image quality of prostate magnetic resonance imaging and PI-RADS scores
Original language description
Background: The diagnostic accuracy of prostate magnetic resonance imaging (MRI) is highly dependent on image quality. Although the effects of spasmolytics and rectal preparation have been previously studied, the findings remain inconsistent and fail to address other critical modifiable factors. This study aimed to evaluate the impact of various modifiable factors on prostate MRI image quality and their subsequent influence on Prostate Imaging Reporting and Data System (PI-RADS) scoring. Methods: Fifty-six consecutive patients who underwent 3T multiparametric MRI (mpMRI) with the administration of hyoscine butylbromide (HB+) and at least one 3T mpMRI without HB (HB-) <=3 years earlier were retrospectively evaluated. Two radiologists performed morphometry of the prostate, bladder, rectum, and abdomen and evaluated image quality, artifacts, and motion on a five-point scale and T2 and diffusion-weighted imaging (DWI) PI-RADS v2.1 scores. The influence of HB, rectum and bladder distension, breathing motion, and examination hour were analyzed. Results: The sharpness and overall image quality of T2 images were significantly better in HB+ compared to HB- (P=0.0047 and P=0.013). T2 motion artifacts were reduced earlier in the day (ρ=0.32, P=0.017). DWI susceptibility artifact correlated with patient diameter (ρ=0.40, P=0.002), but not with rectum diameter (ρ=0.09, P=0.51) or gas content (ρ=0.13, P=0.33). Examinations later in the day were associated with increased motion artifacts on T2 [hazard ratio (HR) =1.36]. T2 and DWI scores were influenced by bladder volume, breathing motion, and rectal air, but not by HB. Breathing motion negatively impacted overall image quality (HR =1.24), and DWI susceptibility artifacts (HR =1.22). Conclusions: HB administration, daytime, and breathing motion have significant influence on image quality of prostate MRI. The gas content of the rectum influences T2 image quality and T2 scores. Bladder filling is associated with reduced breathing motion, subsequently affecting DWI scores.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30224 - Radiology, nuclear medicine and medical imaging
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2025
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Quantitative Imaging in Medicine and Surgery
ISSN
2223-4292
e-ISSN
2223-4306
Volume of the periodical
15
Issue of the periodical within the volume
3
Country of publishing house
HK - HONG KONG
Number of pages
11
Pages from-to
2433-2443
UT code for WoS article
001470488000007
EID of the result in the Scopus database
2-s2.0-86000350285