The LJ System-Development and Validation of a Reliable and Simple Device for Bronchoscopic Measurement of Distances Within the Tracheobronchial Tree

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00064165%3A_____%2F25%3A10498398" target="_blank" >RIV/00064165:_____/25:10498398 - isvavai.cz</a>

  • Alternative codes found

    RIV/68407700:21220/25:00384018 RIV/00216208:11110/25:10498398

  • Result on the web

    <a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=u-u_yLJPK0" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=u-u_yLJPK0</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.3390/diagnostics15080954" target="_blank" >10.3390/diagnostics15080954</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    The LJ System-Development and Validation of a Reliable and Simple Device for Bronchoscopic Measurement of Distances Within the Tracheobronchial Tree

  • Original language description

    Background: The accurate measurement of the distances within the airways during bronchoscopy is necessary for diagnostic purposes; however, a reliable and simple device does not exist. Methods: The LJ system, consisting of a probe, a box with a display, an encoder, and a microcontroller, has been developed, and its prototype has been tested in vitro and validated in clinical practice in suitable procedures of interventional bronchoscopy. Results: In vitro, the device measurements showed a good correlation with the control performed with a digital caliper. Subsequently, ten patients were included in a pilot study evaluating this novel prototype of a measurement device. The device was used on four patients with tracheal stenosis indicated for Y-stent placement, four patients indicated for open surgery, and two cases of tracheoesophageal fistula. The measurements have been validated using computed tomography imaging or by direct inspection and measurement during open surgical procedures. Conclusions: The first experience and pilot study evaluating this novel instrument for distance measurements during interventional bronchology procedures showed that the LJ device can provide precise readings of the distance from the vocal cords, the lengths of tracheal stenoses, or the size of tumorous and other lesions. Its use might be widened to other endoscopic indications.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    30203 - Respiratory systems

Result continuities

  • Project

  • Continuities

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2025

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Diagnostics

  • ISSN

    2075-4418

  • e-ISSN

    2075-4418

  • Volume of the periodical

    15

  • Issue of the periodical within the volume

    8

  • Country of publishing house

    CH - SWITZERLAND

  • Number of pages

    10

  • Pages from-to

    954

  • UT code for WoS article

    001475083200001

  • EID of the result in the Scopus database

    2-s2.0-105003599946