Lung tissue density measured by low-dose CT during pulmonary perfusion SPECT/CT as a tool for differentiation pulmonary embolism from chronic obstructive pulmonary disease
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00064173%3A_____%2F13%3AN0000008" target="_blank" >RIV/00064173:_____/13:N0000008 - isvavai.cz</a>
Result on the web
<a href="http://dx.doi.org/10.1016/j.crvasa.2013.10.002" target="_blank" >http://dx.doi.org/10.1016/j.crvasa.2013.10.002</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.crvasa.2013.10.002" target="_blank" >10.1016/j.crvasa.2013.10.002</a>
Alternative languages
Result language
angličtina
Original language name
Lung tissue density measured by low-dose CT during pulmonary perfusion SPECT/CT as a tool for differentiation pulmonary embolism from chronic obstructive pulmonary disease
Original language description
Objective: Interpretation of lung perfusion scintigraphy in patients with suspected pulmonary embolism (PE) is difficult, especially in the presence of chronic obstructive pulmonary disease (COPD) and most often has to be combined with pulmonary ventilation scintigraphy. We investigated the data from the CT portion of pulmonary perfusion SPECT/CT for possible resolution of this problem. Methods: We assessed data from 12 patients (4 male, 8 female, mean age 68 y) with perfusion defects, 6 with PE, 6 with COPD. Final interpretation was based on ventilation/perfusion (V/Q) scintigraphy (mismatch or match). Lung tissue density was measured from the CT portion of pulmonary perfusion SPECT/CT. We analyzed 32 areas in mismatch defects (PE), 25 areas in match defects (COPD), and 17 areas without perfusion defects. Perfusion defects cause easily identifiable on X-ray (e.g. effusion) were excluded from the analysis. Data were compared with ANOVA test and Bonferroni post-hoc analysis, p<0.05 was considered statistically significant. Results: The mean lung tissue density in areas without perfusion defects was -758 HU, in V/Q mismatch defects (PE) -695 HU, and in V/Q match defects (COPD) -900 HU. The differences of lung tissue density was statistically significant (p=0.000). Conclusion: Lung tissue density measured by CT is significantly lower in perfusion defects caused by COPD than in those caused by PE. We believe this data could be used as an adjunct in interpretation of pulmonary perfusion studies and potentially help avoid the performance of ventilation scintigraphy in patients with suspected PE.
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
FS - Medical facilities, apparatus and equipment
OECD FORD branch
—
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2013
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Cor et Vasa
ISSN
0010-8650
e-ISSN
—
Volume of the periodical
55
Issue of the periodical within the volume
6
Country of publishing house
CZ - CZECH REPUBLIC
Number of pages
5
Pages from-to
e492-e496
UT code for WoS article
—
EID of the result in the Scopus database
2-s2.0-84893662401