Fully automated measurement of aortic root anatomy using Philips HeartNavigator computed tomography software: fast, accurate, or both?
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00064173%3A_____%2F22%3A43923334" target="_blank" >RIV/00064173:_____/22:43923334 - isvavai.cz</a>
Alternative codes found
RIV/00216208:11120/22:43923334
Result on the web
<a href="https://doi.org/10.1093/eurheartjsupp/suac005" target="_blank" >https://doi.org/10.1093/eurheartjsupp/suac005</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1093/eurheartjsupp/suac005" target="_blank" >10.1093/eurheartjsupp/suac005</a>
Alternative languages
Result language
angličtina
Original language name
Fully automated measurement of aortic root anatomy using Philips HeartNavigator computed tomography software: fast, accurate, or both?
Original language description
Cardiac computed tomography (CT) is vital for safety and efficacy of transcatheter aortic valve implantation (TAVI). We aimed to determine the accuracy of fully automated CT analysis of aortic root anatomy before TAVI by Philips HeartNavigator software. This prospective, academic, single-centre study enrolled 128 consecutive patients with native aortic valve stenosis considered for TAVI. Automated HeartNavigator software was compared to the standard manual CT analysis by experienced operators using FluoroCT software. The sizing of the aortic annulus by perimeter and area significantly differed between both methods: mean perimeter was 76.43 mm vs. 77.52 mm (P < 0.0001) using manual FluoroCT vs. automated HeartNavigator software; mean area was 465 mm(2) vs. 476 mm(2) (P < 0.0001). Interindividual variability testing revealed mean differences between the two operators were 1.21 mm for the aortic annulus perimeter and 9 mm(2) for the aortic annulus area. The hypothetical self-expandable transcatheter prosthesis sizing resulted in 80% agreement in 80% of cases. The time required to perform the automated CT analysis was significantly shorter than the time required for manual analysis (mean 17.8 min vs. 2.1 min, P < 0.0001). Philips HeartNavigator fully automated software for pre-TAVI CT analysis is a promising technology. Differences detected in aortic annulus dimensions are small and similar to the variability of manual CT analysis. Automated prediction of optimal fluoroscopic viewing angles is accurate. Correct transcatheter prosthesis sizing requires clinical oversight.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30201 - Cardiac and Cardiovascular systems
Result continuities
Project
<a href="/en/project/EF16_026%2F0008388" target="_blank" >EF16_026/0008388: Interventional treatment of life-threatening cardiovascular diseases</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2022
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
European Heart Journal: Supplements
ISSN
1520-765X
e-ISSN
1554-2815
Volume of the periodical
24
Issue of the periodical within the volume
Suppl. B
Country of publishing house
GB - UNITED KINGDOM
Number of pages
6
Pages from-to
"B36"-"B41"
UT code for WoS article
000780488200008
EID of the result in the Scopus database
2-s2.0-85143655706