Refractive Outcome After Corneal Lenticule Implantation Ex Vivo Non-Human Study
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00064173%3A_____%2F23%3A43925327" target="_blank" >RIV/00064173:_____/23:43925327 - isvavai.cz</a>
Alternative codes found
RIV/00216208:11120/23:43925327
Result on the web
<a href="https://doi.org/10.1080/02713683.2023.2192447" target="_blank" >https://doi.org/10.1080/02713683.2023.2192447</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1080/02713683.2023.2192447" target="_blank" >10.1080/02713683.2023.2192447</a>
Alternative languages
Result language
angličtina
Original language name
Refractive Outcome After Corneal Lenticule Implantation Ex Vivo Non-Human Study
Original language description
PURPOSE: To evaluate changes in corneal refractive parameters after implantation of a stromal lenticule of different thickness. We assume that the refractive outcome depends on the optical power of the used lenticule. METHODS: We conducted an ex-vivo non-human study on 33 normotonic porcine eyeballs divided into two groups, for 4D and 8D human lenticule implantation. Corneal stromal lenticules were obtained as a by-product from a laser procedure ReLEx SMILE. We evaluated corneal refractive parameters measured on Oculus Pentacam(C) device before and immediately after the intrastromal lenticule implantation. RESULTS: There was no statistically significant difference in corneal refractive parameters between the eyeball groups before lenticule implantation. In both groups, the intrastromal implantation in the depth of 300um led to a significant increase of central corneal pachymetry and corneal anterior steepening. In the 4D group the average central corneal pachymetry increased from 903 +- 124.59 to 1230 +- 148.99 (p = 0.0022) and in 8D group from 733.35 +- 69.60 to 1109 +- 161.64 (p = 0.0008). Induced changes in other studied parameters were not statistically significant, Kmax changed from 45.57 +- 2.78 to 72.07 +- 16.83 (p = 0.0094) and Km front from 40.72 +- 1.60 to 48.87 +- 5.83 (p = 0.0037) in 4D group and in the 8D group average Kmax increased from 42.22 +- 1.54 to 62.95 +- 12.67 (p = 0.0001) and K2 front 40.46 +- 1.64 to 51.51 +- 9.63 (p = 0.0037). There were no significant differences in refractive changes between the 4D and 8D groups after lenticule implantation. CONCLUSION: Intrastromal corneal lenticule implantation induces changes in corneal refractive parameters. In both groups, the implantation induced a significant increase of an anterior corneal steepening without any significant influence on posterior corneal flattening. Corneal lenticule implantation did not lead to any significant change of corneal astigmatism. However, in order to have more precise data for future clinical applications we need to continue with the experiments and verify the results on human corneas.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30207 - Ophthalmology
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2023
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Current Eye Research
ISSN
0271-3683
e-ISSN
1460-2202
Volume of the periodical
48
Issue of the periodical within the volume
7
Country of publishing house
US - UNITED STATES
Number of pages
6
Pages from-to
645-650
UT code for WoS article
000962638700001
EID of the result in the Scopus database
2-s2.0-85151660475