Prediction of Fluid Responsiveness Using Combined End-Expiratory and End-Inspiratory Occlusion Tests in Cardiac Surgical Patients
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00064173%3A_____%2F23%3A43925330" target="_blank" >RIV/00064173:_____/23:43925330 - isvavai.cz</a>
Alternative codes found
RIV/00216208:11110/23:10458574 RIV/00216208:11120/23:43925330 RIV/00064165:_____/23:10458574
Result on the web
<a href="https://doi.org/10.3390/jcm12072569" target="_blank" >https://doi.org/10.3390/jcm12072569</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3390/jcm12072569" target="_blank" >10.3390/jcm12072569</a>
Alternative languages
Result language
angličtina
Original language name
Prediction of Fluid Responsiveness Using Combined End-Expiratory and End-Inspiratory Occlusion Tests in Cardiac Surgical Patients
Original language description
End-expiratory occlusion (EEO) and end-inspiratory occlusion (EIO) tests have been successfully used to predict fluid responsiveness in various settings using calibrated pulse contour analysis and echocardiography. The aim of this study was to test if respiratory occlusion tests predicted fluid responsiveness reliably in cardiac surgical patients with protective ventilation. This single-centre, prospective study, included 57 ventilated patients after elective coronary artery bypass grafting who were indicated for fluid expansion. Baseline echocardiographic measurements were obtained and patients with significant cardiac pathology were excluded. Cardiac index (CI), stroke volume and stroke volume variation were recorded using uncalibrated pulse contour analysis at baseline, after performing EEO and EIO tests and after volume expansion (7 mL/kg of succinylated gelatin). Fluid responsiveness was defined as an increase in cardiac index by 15%. Neither EEO, EIO nor their combination predicted fluid responsiveness reliably in our study. After a combined EEO and EIO, a cut-off point for CI change of 16.7% predicted fluid responsiveness with a sensitivity of 61.8%, specificity of 69.6% and ROC AUC of 0.593. In elective cardiac surgical patients with protective ventilation, respiratory occlusion tests failed to predict fluid responsiveness using uncalibrated pulse contour analysis.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30221 - Critical care medicine and Emergency medicine
Result continuities
Project
—
Continuities
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Others
Publication year
2023
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Journal of Clinical Medicine
ISSN
2077-0383
e-ISSN
2077-0383
Volume of the periodical
12
Issue of the periodical within the volume
7
Country of publishing house
CH - SWITZERLAND
Number of pages
12
Pages from-to
2569
UT code for WoS article
000970011300001
EID of the result in the Scopus database
2-s2.0-85152902169