The Longer, the Better: Continuous Glucose Monitoring Use for GREATER-THAN OR EQUAL TO90% Is Superior to 70%-89% in Achieving Tighter Glycemic Outcomes in Children with Type 1 Diabetes
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00064173%3A_____%2F25%3A43927839" target="_blank" >RIV/00064173:_____/25:43927839 - isvavai.cz</a>
Result on the web
<a href="https://doi.org/10.1089/dia.2024.0472" target="_blank" >https://doi.org/10.1089/dia.2024.0472</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1089/dia.2024.0472" target="_blank" >10.1089/dia.2024.0472</a>
Alternative languages
Result language
angličtina
Original language name
The Longer, the Better: Continuous Glucose Monitoring Use for GREATER-THAN OR EQUAL TO90% Is Superior to 70%-89% in Achieving Tighter Glycemic Outcomes in Children with Type 1 Diabetes
Original language description
Objective: The recommended threshold for the time spent on continuous glucose monitoring (CGM) is established at 70%. However, glucose outcomes in children with type 1 diabetes (CwD) using CGM for a different proportion of time within this threshold have not been evaluated yet. The study aims to compare glycemic parameters among CwD who spent 70%-89% and >=90% on CGM using the population-wide data from the Czech national pediatric diabetes registry ČENDA. Methods: CwD aged <19 years who used real-time CGM >70% of the time and did not change the type of therapy throughout the year 2023 were included and divided into two groups based on the time they spent on CGM-70%-89% versus >=90%. HbA1c, times in standard glycemic ranges, mean glucose, and coefficient of variability (CV) were compared between the groups and by treatment modalities. Results: Data from 1977 CwD (1035 males and 942 females) were evaluated. Among them, 404 participants (20.4%) used CGM 70%-89% of the time, and 1573 participants (79.6%) >=90% of the time. Compared with the 70-89% group, the >=90% CGM users achieved significantly lower HbA1c levels (51 mmol/mol, 6.8% vs. 58 mmol/mol, 7.4%, P < 0.001), higher time in range (72% vs. 60%, P < 0.001), and lower mean glucose and CV (8.1 mmol/L, 146 mg/dL vs. 9.1 mmol/L, 164 mg/dL and 37% vs. 40%, respectively, both P < 0.001). Analogous results were seen irrespective of the treatment modality. The differences persisted after propensity score adjustment. Conclusion: CGM use for >=90% is associated with tighter glycemic control compared with 70%-89% use. Therefore, it is essential to motivate CwD to use CGM for the longest possible time and search for suitable options to overcome barriers in uninterrupted CGM monitoring.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30202 - Endocrinology and metabolism (including diabetes, hormones)
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2025
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Diabetes Technology & Therapeutics
ISSN
1520-9156
e-ISSN
1557-8593
Volume of the periodical
27
Issue of the periodical within the volume
4
Country of publishing house
US - UNITED STATES
Number of pages
7
Pages from-to
301-307
UT code for WoS article
001390805300001
EID of the result in the Scopus database
2-s2.0-85215668137