Intramedullary nail use for corrective surgery of diaphyseal forearm fractures
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00064203%3A_____%2F09%3A5221" target="_blank" >RIV/00064203:_____/09:5221 - isvavai.cz</a>
Alternative codes found
RIV/00216208:11130/09:5221
Result on the web
—
DOI - Digital Object Identifier
—
Alternative languages
Result language
angličtina
Original language name
Intramedullary nail use for corrective surgery of diaphyseal forearm fractures
Original language description
The aim of this study is to evaluate the results after reoperation of radial- and ulnar diaphyseal fractures using an interlocking intramedullary nail. A cohort of 30 patients, who were treated with a F oreSight (Smith&Nephew, USA) intramedullary nail between the years 2000 and 2005, were included in the study.
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
FJ - Surgery including transplantology
OECD FORD branch
—
Result continuities
Project
<a href="/en/project/NR8927" target="_blank" >NR8927: Treatment of diaphyseal forearm fractures with small locking compression plate and intramedullary nailing - prospective, randomized study</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2009
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Scripta Medica Facultatis Medicae Universitatis Brunensis Masarykianae
ISSN
1211-3395
e-ISSN
—
Volume of the periodical
82
Issue of the periodical within the volume
2
Country of publishing house
CZ - CZECH REPUBLIC
Number of pages
10
Pages from-to
—
UT code for WoS article
—
EID of the result in the Scopus database
—