Nonactivated thromboelastometry able to detect fibrinolysis in contrast to activated methods (EXTEM, INTEM) in a bleeding patient
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00064203%3A_____%2F16%3A10332511" target="_blank" >RIV/00064203:_____/16:10332511 - isvavai.cz</a>
Alternative codes found
RIV/00216208:11130/16:10332511
Result on the web
<a href="http://dx.doi.org/10.1097/MBC.0000000000000479" target="_blank" >http://dx.doi.org/10.1097/MBC.0000000000000479</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1097/MBC.0000000000000479" target="_blank" >10.1097/MBC.0000000000000479</a>
Alternative languages
Result language
angličtina
Original language name
Nonactivated thromboelastometry able to detect fibrinolysis in contrast to activated methods (EXTEM, INTEM) in a bleeding patient
Original language description
Rotational thromboelastometry (ROTEM) is increasingly used in practice to monitor coagulation status of severely bleeding patients and it helps to provide aimed therapy. The main advantage of ROTEM is detection of fibrinolysis. To get fast results, the reagents for activation, either extrinsic or intrinsic pathway of coagulation, are used. Although this method gives information about whole blood coagulation, in some cases, the patient is bleeding despite normal values of ROTEM. We present a case of a bleeding patient with normal values of activated ROTEM method (EXTEM, INTEM). However, nonactivated method (NATEM) was able to detect fibrinolysis and no clot was found in the cuvette. When tranexamic acid was added to the cuvette, the trace came back to normal value and a clot was formed inside the cuvette. According to this finding, the patient was effectively treated with antifibrinolytic drugs and stopped bleeding. In this case, we want to demonstrate that NATEM, as nonactivated ROTEM, seems to be more sensitive to coagulation changes, especially in detection of fibrinolysis, than activated ROTEM methods.
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
FD - Oncology and haematology
OECD FORD branch
—
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2016
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Blood Coagulation & Fibrinolysis
ISSN
0957-5235
e-ISSN
—
Volume of the periodical
27
Issue of the periodical within the volume
7
Country of publishing house
US - UNITED STATES
Number of pages
3
Pages from-to
828-830
UT code for WoS article
000385529500016
EID of the result in the Scopus database