All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Inter-comparison of quantitative imaging of lutetium-177 (Lu-177) in European hospitals

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00064203%3A_____%2F18%3A10377431" target="_blank" >RIV/00064203:_____/18:10377431 - isvavai.cz</a>

  • Result on the web

    <a href="https://doi.org/10.1186/s40658-018-0213-z" target="_blank" >https://doi.org/10.1186/s40658-018-0213-z</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1186/s40658-018-0213-z" target="_blank" >10.1186/s40658-018-0213-z</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Inter-comparison of quantitative imaging of lutetium-177 (Lu-177) in European hospitals

  • Original language description

    Background: This inter-comparison exercise was performed to demonstrate the variability of quantitative SPECT/CT imaging for lutetium-177 (Lu-177) in current clinical practice. Our aim was to assess the feasibility of using international inter-comparison exercises as a means to ensure consistency between clinical sites whilst enabling the sites to use their own choice of quantitative imaging protocols, specific to their systems. Dual-compartment concentric spherical sources of accurately known activity concentrations were prepared and sent to seven European clinical sites. The site staff were not aware of the true volumes or activity within the sources-they performed SPECT/CT imaging of the source, positioned within a water-filled phantom, using their own choice of parameters and reported their estimate of the activities within the source. Results: The volumes reported by the participants for the inner section of the source were all within 29% of the true value and within 60% of the true value for the outer section. The activities reported by the participants for the inner section of the source were all within 20% of the true value, whilst those reported for the outer section were up to 83% different to the true value. Conclusions: A variety of calibration and segmentation methods were used by the participants for this exercise which demonstrated the variability of quantitative imaging across clinical sites. This paper presents a method to assess consistency between sites using different calibration and segmentation methods.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>SC</sub> - Article in a specialist periodical, which is included in the SCOPUS database

  • CEP classification

  • OECD FORD branch

    30224 - Radiology, nuclear medicine and medical imaging

Result continuities

  • Project

  • Continuities

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2018

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    EJNMMI Physics [online]

  • ISSN

    2197-7364

  • e-ISSN

  • Volume of the periodical

    5

  • Issue of the periodical within the volume

    neuvedeno

  • Country of publishing house

    CH - SWITZERLAND

  • Number of pages

    18

  • Pages from-to

  • UT code for WoS article

    000440432700001

  • EID of the result in the Scopus database

    2-s2.0-85051062090