Pediatric catheter ablation at the beginning of the 21st century: results from the European Multicenter Pediatric Catheter Ablation Registry 'EUROPA'
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00064203%3A_____%2F21%3A10418065" target="_blank" >RIV/00064203:_____/21:10418065 - isvavai.cz</a>
Alternative codes found
RIV/00216208:11130/21:10418065
Result on the web
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=WUaEelXh2g" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=WUaEelXh2g</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1093/europace/euaa325" target="_blank" >10.1093/europace/euaa325</a>
Alternative languages
Result language
angličtina
Original language name
Pediatric catheter ablation at the beginning of the 21st century: results from the European Multicenter Pediatric Catheter Ablation Registry 'EUROPA'
Original language description
AIMS: Contemporary data from prospective multicentre registries on catheter ablation in pediatric patients are sparse. Aim of the European Pediatric Catheter Ablation Registry EUROPA was to contribute data to fill this gap of knowledge. METHODS AND RESULTS: From July 2012 to June 2017, data on catheter ablation in pediatric patients (<=18 years of age) including a 1-year follow-up from five European pediatric EP centres were collected prospectively. A total of 683 patients (mean age 12.4 +- 3.9 years, mean body weight 50.2 +- 19 kg) were enrolled. Target tachycardia was WPW/atrioventricular-nodal re-entrant tachycardia (AVRT) in 380 (55.7%) patients, AVNRT in 230 (33.8%) patients, ventricular tachycardia (VT) in 24 (3.5) patients, focal atrial tachycardia (FAT) in 20 (2.9%) patients, IART in 14 (2%) patients, and junctional ectopic tachycardia in 3 (0.45) patients. Overall procedural success was 95.6%. Compared with all other substrates, success was significantly lower in FAT patients (80%, n = 16, P = 0.001). Mean procedure duration was 136 +- 67 min and mean fluoroscopy time was 4.9 +- 6.8 min. Major complications occurred in 0.7% of the patients. No persisting AV block requiring permanent pacing was reported. At 1-year follow-up (605/683 patients, 95%), tachycardia recurrence was reported in 7.8% of patients. Recurrence after VT ablation (33%) was significantly higher (P = 0.001) than after ablation of all other substrates. CONCLUSION: The present study proves overall high efficacy and safety of catheter ablation of various tachycardia substrates in pediatric patients. Of note, complication rate was exceptionally low. Long-term success was high except for patients after VT ablation.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30201 - Cardiac and Cardiovascular systems
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2021
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Europace
ISSN
1099-5129
e-ISSN
—
Volume of the periodical
23
Issue of the periodical within the volume
3
Country of publishing house
GB - UNITED KINGDOM
Number of pages
10
Pages from-to
431-440
UT code for WoS article
000637048400016