Detection of interictal epileptiform discharges in an extended scalp EEG array and high-density EEG - A prospective multicenter study
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00064203%3A_____%2F22%3A10442544" target="_blank" >RIV/00064203:_____/22:10442544 - isvavai.cz</a>
Alternative codes found
RIV/00216208:11130/22:10442544
Result on the web
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=D8a6pkboWZ" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=D8a6pkboWZ</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1111/epi.17246" target="_blank" >10.1111/epi.17246</a>
Alternative languages
Result language
angličtina
Original language name
Detection of interictal epileptiform discharges in an extended scalp EEG array and high-density EEG - A prospective multicenter study
Original language description
OBJECTIVES: High counts of averaged interictal epileptiform discharges (IEDs) are key components of accurate interictal electric source imaging (ESI) in patients with focal epilepsy. Automated detections may be time-efficient, but they need to identify the correct IED types. Thus, we compared semiautomated and automated detection of IED types in long-term video EEG monitoring (LTM) using an extended scalp EEG array and short-term high-density EEG (hdEEG) with visual detection of IED types and the seizure onset zone (SOZ). METHODS: We prospectively recruited consecutive patients from four epilepsy centers who underwent both LTM with 40 electrodes scalp EEG and short-term hdEEG with 256 electrodes. Only patients with a single circumscribed SOZ in LTM were included. In LTM and hdEEG, IED types were identified visually, semiautomatically and automatically. Concordances of semiautomated and automated detections in LTM and hdEEG as well as visual detections in hdEEG were compared against visually detected IED types and the SOZ in LTM. RESULTS: Fifty-two out of 62 patients with LTM and hdEEG were included. The most frequent IED types per patient, detected semiautomatically and automatically in LTM and visually in hdEEG, were significantly concordant with the most frequently visually identified IED type in LTM and the SOZ. Semiautomated and automated detections of IED types in hdEEG were significantly concordant with visually identified IED types in LTM only when IED types with more than 50 detected single IEDs were selected. The threshold of 50 detected IED in hdEEG was reached in half of the patients. For all IED types per patient, agreement between visual and semiautomated detections in LTM was high. SIGNIFICANCE: Semiautomated and automated detections of IED types in LTM show significant agreement with visually detected IED types and the SOZ. In short-term hdEEG, semiautomated detections of IED types are concordant with visually detected IED types and the SOZ in LTM if high IED counts were detected.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30103 - Neurosciences (including psychophysiology)
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2022
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Epilepsia
ISSN
0013-9580
e-ISSN
1528-1167
Volume of the periodical
63
Issue of the periodical within the volume
7
Country of publishing house
US - UNITED STATES
Number of pages
11
Pages from-to
1619-1629
UT code for WoS article
000782769700001
EID of the result in the Scopus database
2-s2.0-85130402343