New method for estimation of fluence complexity in IMRT fields and correlation with gamma analysis

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00064211%3A_____%2F15%3A%230000467" target="_blank" >RIV/00064211:_____/15:#0000467 - isvavai.cz</a>

  • Result on the web

    <a href="http://iopscience.iop.org" target="_blank" >http://iopscience.iop.org</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1088/1742-6596/573/1/012056" target="_blank" >10.1088/1742-6596/573/1/012056</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    New method for estimation of fluence complexity in IMRT fields and correlation with gamma analysis

  • Original language description

    A new method for estimation of fluence complexity in Intensity Modulated Radiation Therapy (IMRT) fields is proposed. Unlike other previously published works, it is based on portal images calculated by the Portal Dose Calculation algorithm in Eclipse (version 8.6, Varian Medical Systems) in the plane of the EPID aS500 detector (Varian Medical Systems). Fluence complexity is given by the number and the amplitudes of dose gradients in these matrices. Our method is validated using a set of clinical plans where fluence has been smoothed manually so that each plan has a different level of complexity. Fluence complexity calculated with our tool is in accordance with the different levels of smoothing as well as results of gamma analysis, when calculated and measured dose matrices are compared. Thus, it is possible to estimate plan complexity before carrying out the measurement. If appropriate thresholds are determined which would distinguish between acceptably and overly modulated plans, this might save time in the re-planning and re-measuring process.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)

  • CEP classification

    FS - Medical facilities, apparatus and equipment

  • OECD FORD branch

Result continuities

  • Project

  • Continuities

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2015

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Journal of Physics Conference Series

  • ISSN

    1742-6588

  • e-ISSN

  • Volume of the periodical

    573

  • Issue of the periodical within the volume

    012056

  • Country of publishing house

    GB - UNITED KINGDOM

  • Number of pages

    6

  • Pages from-to

    1-5

  • UT code for WoS article

    000352600500056

  • EID of the result in the Scopus database