Valve Hemodynamics by Valve Size and 1-Year Survival Following Implantation of the Portico Valve in the Multicenter CONFIDENCE Registry

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00098892%3A_____%2F24%3A10158636" target="_blank" >RIV/00098892:_____/24:10158636 - isvavai.cz</a>

  • Result on the web

    <a href="https://www.sciencedirect.com/science/article/pii/S2474870623001203?via%3Dihub" target="_blank" >https://www.sciencedirect.com/science/article/pii/S2474870623001203?via%3Dihub</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1016/j.shj.2023.100226" target="_blank" >10.1016/j.shj.2023.100226</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Valve Hemodynamics by Valve Size and 1-Year Survival Following Implantation of the Portico Valve in the Multicenter CONFIDENCE Registry

  • Original language description

    Background: The CONtrolled delivery For ImproveD outcomEs with cliNiCal Evidence registry was initiated to characterize the clinical safety and device performance from experienced transcatheter aortic valve implantation (TAVI) centers in Europe and Australia that use the Portico valve to treat patients with severe aortic stenosis. We herein report for the first time the valve performance at 30-day across all implanted valve sizes and the 1-year survival from this registry. Methods: This was a prospective, multicenter, single-arm observational clinical investigation of patients clinically indicated for implantation of a Portico valve in experienced TAVI centers. Patients were treated with a commercially available valve (size 23, 25, 27, or 29 mm) using either the first-generation delivery system (DS) (n = 501) or the second-generation (FlexNav) DS (n = 500). Adverse events were adjudicated by an independent clinical events committee according to Valve Academic Research Consortium-2 criteria. Echocardiographic outcomes were assessed at 30 days by an independent core laboratory, and a survival check was performed at 1 year. Results: We enrolled 1001 patients (82.0 years, 62.5% female, 63.7% New York Heart Association functional class III/IV at baseline) from 27 clinical sites in 8 countries across Europe and one site in Australia. Implantation of a single valve was successful in 97.5% of subjects. Valve hemodynamics at 30 days were substantially improved relative to baseline, with large aortic valve areas and low mean gradients across all implanted valve sizes (aortic valve areas were 1.7 ± 0.4, 1.7 ± 0.5, 1.8 ± 0.5, and 2.0 ± 0.5 cm2, and mean gradients were 7.0 ± 2.7, 7.5 ± 4.7, 7.3 ± 3.3, and 6.4 ± 3.3 mmHg for 23, 25, 27, and 29 mm valve sizes, respectively). Across all implanted valve sizes, most patients (77.1%) had no patient-prosthesis mismatch. Death from any cause within 1 year occurred in 13.7% of the patients in the first-generation DS group as compared with 11.0% in the second-generation DS group (p = 0.2). Conclusions: The Portico valve demonstrated excellent hemodynamic performance across all valve sizes in a large cohort of subjects implanted in experienced TAVI centers. One-year survival rates were favorable when using both the first-generation and second-generation (FlexNav) DSs in this high-risk cohort.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    30201 - Cardiac and Cardiovascular systems

Result continuities

  • Project

  • Continuities

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2024

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Structural Heart

  • ISSN

    2474-8706

  • e-ISSN

    2474-8714

  • Volume of the periodical

    8

  • Issue of the periodical within the volume

    1

  • Country of publishing house

    US - UNITED STATES

  • Number of pages

    9

  • Pages from-to

    100226

  • UT code for WoS article

    001167655800001

  • EID of the result in the Scopus database

    2-s2.0-85176416379