Contribution of remote monitoring to the early diagnosis of implantable cardioverter-defibrillator shocks in the patient with cardiac resynchronisation therapy

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00159816%3A_____%2F13%3A00060799" target="_blank" >RIV/00159816:_____/13:00060799 - isvavai.cz</a>

  • Result on the web

    <a href="http://dx.doi.org/10.1016/j.crvasa.2012.12.003" target="_blank" >http://dx.doi.org/10.1016/j.crvasa.2012.12.003</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1016/j.crvasa.2012.12.003" target="_blank" >10.1016/j.crvasa.2012.12.003</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Contribution of remote monitoring to the early diagnosis of implantable cardioverter-defibrillator shocks in the patient with cardiac resynchronisation therapy

  • Original language description

    We present the case of a 68-year-old man with coronary artery disease and a history of recurrent myocardial infarctions, having left ventricular ejection fraction 25% in NYHA functional class III. The patient received a biventricular cardioverter-defibrillator (ICD) Biotronik Lumax 340 HF-T in November 2008 from the primary prophylactic indication. Remote monitoring using the Biotronik Home MonitoringTM (HM) system was activated since device implantation. Up to April 2012 the patient received five shocks including 3 appropriate VF therapies and 2 inappropriate ICD shocks (due to T-wave oversensing and atrial flutter degenerating to VF after ATPs). All arrhythmic events were promptly detected by the HM system with a rapid consequent pharmacological andnon-pharmacological intervention (radiofrequency catheter ablation of atrial arrhythmia and reprogramming the device). This case points out that prophylactic ICD implantation is a justifiable method for the prevention of arrhythmic death

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)

  • CEP classification

    FA - Cardiovascular diseases including cardio-surgery

  • OECD FORD branch

Result continuities

  • Project

    <a href="/en/project/ED1.100%2F02%2F0123" target="_blank" >ED1.100/02/0123: St. Anne´s University Hospital Brno - International Clinical Research Center (FNUSA-ICRC)</a><br>

  • Continuities

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2013

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Cor et Vasa

  • ISSN

    0010-8650

  • e-ISSN

  • Volume of the periodical

    55

  • Issue of the periodical within the volume

    3

  • Country of publishing house

    CZ - CZECH REPUBLIC

  • Number of pages

    4

  • Pages from-to

    "E281"-"E284"

  • UT code for WoS article

  • EID of the result in the Scopus database