Letter by Zagatina et al. regarding the article, "Three-dimensional speckle strain echocardiography is more accurate and efficient than 2D strain in the evaluation of left ventricular function"
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00159816%3A_____%2F14%3A00061531" target="_blank" >RIV/00159816:_____/14:00061531 - isvavai.cz</a>
Result on the web
<a href="http://dx.doi.org/10.1016/j.ijcard.2014.09.186" target="_blank" >http://dx.doi.org/10.1016/j.ijcard.2014.09.186</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.ijcard.2014.09.186" target="_blank" >10.1016/j.ijcard.2014.09.186</a>
Alternative languages
Result language
angličtina
Original language name
Letter by Zagatina et al. regarding the article, "Three-dimensional speckle strain echocardiography is more accurate and efficient than 2D strain in the evaluation of left ventricular function"
Original language description
We read the recently published paper by Xu et al. [1] regarding new and very interesting data of the 3D speckle tracking analysis. The authors have shown the better correlation between3Dspeckletracking and ejection fraction in comparison with the correlation between 2D speckle tracking and ejection fraction measuring by 3D method. After that, they concluded that 3D speckle tracking echocardiography " is more accurate than2D speckle trackingin theevaluation of leftventric- ular function. " We think thisconclusion is not valid; " ejection fraction " and " left ventricular function " are not synonymous. Ejection fraction is one of the parameters that can describe one of the components of left ventricular function - global systolic contraction - this parameter is not exhaustive for the whole ventricular or even systolic function. If theejection fractionwould be theequivalentof the whole left ventricu- lar function, why do we use other parameters, for example, the speckle tracking analysis
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
FA - Cardiovascular diseases including cardio-surgery
OECD FORD branch
—
Result continuities
Project
<a href="/en/project/ED1.100%2F02%2F0123" target="_blank" >ED1.100/02/0123: St. Anne´s University Hospital Brno - International Clinical Research Center (FNUSA-ICRC)</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2014
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
International Journal of Cardiology
ISSN
0167-5273
e-ISSN
—
Volume of the periodical
177
Issue of the periodical within the volume
2
Country of publishing house
IE - IRELAND
Number of pages
1
Pages from-to
634
UT code for WoS article
000345232200099