Absolute Ultrasound Perfusion Parameter Quantification of a Tissue-Mimicking Phantom Using Bolus Tracking

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00159816%3A_____%2F15%3A00063023" target="_blank" >RIV/00159816:_____/15:00063023 - isvavai.cz</a>

  • Alternative codes found

    RIV/68081731:_____/15:00451614 RIV/00209805:_____/15:#0000698 RIV/00216305:26220/15:PU114103

  • Result on the web

    <a href="http://dx.doi.org/10.1109/TUFFC.2014.006896" target="_blank" >http://dx.doi.org/10.1109/TUFFC.2014.006896</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1109/TUFFC.2014.006896" target="_blank" >10.1109/TUFFC.2014.006896</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Absolute Ultrasound Perfusion Parameter Quantification of a Tissue-Mimicking Phantom Using Bolus Tracking

  • Original language description

    This study presents three methods for absolute quantification in ultrasound perfusion analysis based on bolus tracking. The first two methods deconvolve the perfusion time sequence with a measured AIF, using a nonparametric or a parametric model of the tissue residue function, respectively. The third method is a simplified approach avoiding deconvolution by assuming a narrow AIF. A phantom with a dialyzer filter as a tissue-mimicking model was used for evaluation. Estimated mean transit times and blood volumes were compared with the theoretical values. A match with a maximum error of 12% was achieved.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)

  • CEP classification

    FS - Medical facilities, apparatus and equipment

  • OECD FORD branch

Result continuities

  • Project

    Result was created during the realization of more than one project. More information in the Projects tab.

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)

Others

  • Publication year

    2015

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control

  • ISSN

    0885-3010

  • e-ISSN

  • Volume of the periodical

    62

  • Issue of the periodical within the volume

    5

  • Country of publishing house

    US - UNITED STATES

  • Number of pages

    5

  • Pages from-to

    983-987

  • UT code for WoS article

    000354455100018

  • EID of the result in the Scopus database