A Wavelet-Based ECG Delineation Method: Adaptation to an Experimental Electrograms with Manifested Global Ischemia
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00159816%3A_____%2F15%3A00063455" target="_blank" >RIV/00159816:_____/15:00063455 - isvavai.cz</a>
Alternative codes found
RIV/00216224:14110/15:00081012 RIV/00216305:26220/15:PU113777
Result on the web
<a href="http://dx.doi.org/10.1007/s13239-015-0224-z" target="_blank" >http://dx.doi.org/10.1007/s13239-015-0224-z</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s13239-015-0224-z" target="_blank" >10.1007/s13239-015-0224-z</a>
Alternative languages
Result language
angličtina
Original language name
A Wavelet-Based ECG Delineation Method: Adaptation to an Experimental Electrograms with Manifested Global Ischemia
Original language description
We present a novel wavelet-based ECG delineation method with robust classification of P wave and T wave. The work is aimed on an adaptation of the method to long-term experimental electrograms (EGs) measured on isolated rabbit heart and to evaluate the effect of global ischemia in experimental EGs on delineation performance. The algorithm was tested on a set of 263 rabbit EGs with established reference points and on human signals using standard Common Standards for Quantitative Electrocardiography Standard Database (CSEDB). On CSEDB, standard deviation (SD) of measured errors satisfies given criterions in each point and the results are comparable to other published works. In rabbit signals, our QRS detector reached sensitivity of 99.87% and positive predictivity of 99.89% despite an overlay of spectral components of QRS complex, P wave and power line noise. The algorithm shows great performance in suppressing J-point elevation and reached low overall error in both, QRS onset (SD = 2.8 ms) and QRS offset (SD = 4.3 ms) delineation. T wave offset is detected with acceptable error (SD = 12.9 ms) and sensitivity nearly 99%. Variance of the errors during global ischemia remains relatively stable, however more failures in detection of T wave and P wave occur. Due to differences in spectral and timing characteristics parameters of rabbit based algorithm have to be highly adaptable and set more precisely than in human ECG signals to reach acceptable performance.
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
ED - Physiology
OECD FORD branch
—
Result continuities
Project
Result was created during the realization of more than one project. More information in the Projects tab.
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2015
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Cardiovascular Engineering and Technology
ISSN
1869-408X
e-ISSN
—
Volume of the periodical
6
Issue of the periodical within the volume
3
Country of publishing house
US - UNITED STATES
Number of pages
12
Pages from-to
364-375
UT code for WoS article
—
EID of the result in the Scopus database
—