Three-dimensional rotational angiography of the left atrium and the oesophagus: the short-term mobility of the oesophagus and the stability of the fused three-dimensional model of the left atrium and the oesophagus during catheter ablation for atrial fibrillation
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00159816%3A_____%2F17%3A00066005" target="_blank" >RIV/00159816:_____/17:00066005 - isvavai.cz</a>
Alternative codes found
RIV/00216224:14110/17:00095977
Result on the web
<a href="http://dx.doi.org/10.1093/europace/euw187" target="_blank" >http://dx.doi.org/10.1093/europace/euw187</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1093/europace/euw187" target="_blank" >10.1093/europace/euw187</a>
Alternative languages
Result language
angličtina
Original language name
Three-dimensional rotational angiography of the left atrium and the oesophagus: the short-term mobility of the oesophagus and the stability of the fused three-dimensional model of the left atrium and the oesophagus during catheter ablation for atrial fibrillation
Original language description
AIMS: The objective of this study was to evaluate the mobility of the oesophagus and the stability of the three-dimensional (3D) model of the oesophagus using 3D rotational angiography (3DRA) of the left atrium (LA) and the oesophagus, fused with live fluoroscopy during catheter ablation for atrial fibrillation. METHODS AND RESULTS: From March 2015 to September 2015, 3DRA of the LA and the oesophagus was performed in 33 patients before catheter ablation for atrial fibrillation. Control contrast oesophagography was performed every 30 min. The positions of the oesophagograms and the 3D model of the LA and the oesophagus were repeatedly measured and compared with the spine. The average shift of the oesophagus ranged from 2.7 +- 2.2 to 5.0 +- 3.5 mm. The average real-time oesophageal shift ranged from 2.7 +- 2.2 to 3.8 +- 3.4 mm. No significant shift was detected until the 90th minute of the procedure. The average shift of the 3D model of the LA and the oesophagus ranged from 1.4 +- 1.8 to 3.3 +- 3.0 mm (right-left direction) and from 0.9 +- 1.2 to 2.2 +- 1.3 mm (craniocaudal direction). During the 2 h procedure, there were no significant shifts of the model. CONCLUSION: During catheter ablation for atrial fibrillation, there is no significant change in the position of the oesophagus until the 90th minute of the procedure and no significant shift in the 3D model of the LA and the oesophagus. The 3D model of the oesophagus reliably depicts the position of the oesophagus during the entire procedure.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30201 - Cardiac and Cardiovascular systems
Result continuities
Project
Result was created during the realization of more than one project. More information in the Projects tab.
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2017
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Europace
ISSN
1099-5129
e-ISSN
—
Volume of the periodical
19
Issue of the periodical within the volume
8
Country of publishing house
GB - UNITED KINGDOM
Number of pages
7
Pages from-to
1310-1316
UT code for WoS article
000408340000008
EID of the result in the Scopus database
—