Long-term outcomes after treatment of bare-metal stent restenosis with paclitaxel-coated balloon catheters or everolimus-eluting stents: 3-year follow-up of the TIS clinical study
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00159816%3A_____%2F18%3A00069327" target="_blank" >RIV/00159816:_____/18:00069327 - isvavai.cz</a>
Alternative codes found
RIV/00216224:14110/18:00105325 RIV/61989592:15110/18:73592411 RIV/00843989:_____/18:E0107409
Result on the web
<a href="http://dx.doi.org/10.1002/ccd.27688" target="_blank" >http://dx.doi.org/10.1002/ccd.27688</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1002/ccd.27688" target="_blank" >10.1002/ccd.27688</a>
Alternative languages
Result language
angličtina
Original language name
Long-term outcomes after treatment of bare-metal stent restenosis with paclitaxel-coated balloon catheters or everolimus-eluting stents: 3-year follow-up of the TIS clinical study
Original language description
Background The efficacy of paclitaxel-eluting balloon catheters (PEB) and drug-eluting stents for treatment of bare-metal stent restenosis (BMS-ISR) have been demonstrated in several studies with follow-up times of 9 to 12 months; however, the long-term outcomes of ISR treatment are less defined. Objectives Methods We aimed to compare the long-term efficacy of PEB and everolimus-eluting stents (EES) for the treatment of BMS-ISR. We analyzed 3-year clinical follow-up data from patients included in the TIS randomized clinical study. A total of 136 patients with BMS-ISR were allocated to receive treatment with either PEB or EES (68 patients with 74 ISR lesions per group). Results Conclusions The PEB and EES groups did not significantly differ in major adverse cardiac events-free survival (MACE; P = .211; including individual events: CV death: P = .622; myocardial infarction: P = .650 or target vessel revascularization: P = .286) at 3-year clinical follow-up. No event-free survival differences were found between the groups regarding overall mortality (P = .818), definite stent thrombosis (P = .165) or the second MACE (P = .270). At the 3-year follow-up, no significant differences in clinical outcomes were found between iopromide-coated PEB and EES for the treatment of BMS-ISR. (; ; NCT01735825).
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30201 - Cardiac and Cardiovascular systems
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2018
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Catheterization and Cardiovascular Interventions
ISSN
1522-1946
e-ISSN
—
Volume of the periodical
92
Issue of the periodical within the volume
6
Country of publishing house
US - UNITED STATES
Number of pages
9
Pages from-to
"E416"-"E424"
UT code for WoS article
000451188300007
EID of the result in the Scopus database
—