Clinical Efficacy, Safety and Tolerability of a New Subcutaneous Immunoglobulin 16.5% (Octanorm [Cutaquig (R)]) in the Treatment of Patients With Primary Immunodeficiencies
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00159816%3A_____%2F19%3A00071167" target="_blank" >RIV/00159816:_____/19:00071167 - isvavai.cz</a>
Alternative codes found
RIV/00216224:14110/19:00109451
Result on the web
<a href="https://www.frontiersin.org/articles/10.3389/fimmu.2019.00040/full" target="_blank" >https://www.frontiersin.org/articles/10.3389/fimmu.2019.00040/full</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3389/fimmu.2019.00040" target="_blank" >10.3389/fimmu.2019.00040</a>
Alternative languages
Result language
angličtina
Original language name
Clinical Efficacy, Safety and Tolerability of a New Subcutaneous Immunoglobulin 16.5% (Octanorm [Cutaquig (R)]) in the Treatment of Patients With Primary Immunodeficiencies
Original language description
Introduction: Subcutaneously administered immunoglobulin (SCIG) is increasingly used to treat patients with primary immunodeficiencies (PIDs). Octanorm (marketed as cutaquig (R) in USA and Canada) is a new 16.5% solution of human SCIG, manufactured by a process based on that of the intravenous preparation (IVIG) octagam (R). Objectives: To investigate the efficacy, safety and tolerability of octanorm in a prospective, open-label, single-arm phase 3 study involving adult and pediatric patients with PIDs (NCT01888484; clinicaltrials. gov/ct2/show/NCT01888484). Methods: Patients who were previously treated with IVIG received a total of 64 weekly SCIG infusions, including 12 weekly infusions during the wash-in/wash-out period, followed by 52 weekly infusions during the evaluation period. Results: A total of 61 patients aged 2-73 years received 3,497 infusions of octanorm. The mean dose per patient was 0.175 g/kg/infusion. The mean calculated dose conversion factor from the patients' previous IVIG dose for octanorm was 1.37. No serious bacterial infections developed during the study. The rate of other infections per person-year during the primary observation period was 3.43 (upper 95% CI 4.57). All but one non-bacterial infection were mild or moderate in intensity. IgG trough levels were constant during the course of the study. Eleven patients (18.0%) experienced 14 mild or moderate systemic adverse events (AEs) related to octanorm. The rate of related AEs per infusion was 0.004. In 76.7% of infusions, no infusion site reactions were observed and only two (0.3%) reactions were deemed severe. The incidence of site reactions decreased with successive infusions. Conclusion: The new 16.5% SCIG octanorm was shown to be efficacious in preventing infections in PIDs, and was well tolerated.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30102 - Immunology
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2019
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Frontiers in Immunology
ISSN
1664-3224
e-ISSN
—
Volume of the periodical
10
Issue of the periodical within the volume
FEB 4
Country of publishing house
CH - SWITZERLAND
Number of pages
12
Pages from-to
40
UT code for WoS article
000457623800001