Apnea and hypopnea characterization using esophageal pressure, respiratory inductance plethysmography, and suprasternal pressure: a comparative study
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00159816%3A_____%2F19%3A00072484" target="_blank" >RIV/00159816:_____/19:00072484 - isvavai.cz</a>
Result on the web
<a href="https://link.springer.com/article/10.1007%2Fs11325-019-01793-8" target="_blank" >https://link.springer.com/article/10.1007%2Fs11325-019-01793-8</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s11325-019-01793-8" target="_blank" >10.1007/s11325-019-01793-8</a>
Alternative languages
Result language
angličtina
Original language name
Apnea and hypopnea characterization using esophageal pressure, respiratory inductance plethysmography, and suprasternal pressure: a comparative study
Original language description
Objectives To determine if recording of suprasternal pressure (SSP) can classify apneas and hypopneas as reliably as respiratory inductance plethysmography (RIP) belts and to compare the two methods to classification with esophageal pressure (Pes), the reference method for assessing respiratory effort. Methods In addition to polysomnographic recordings that included Pes, SSP was recorded. Recordings from 32 patients (25 males, mean age 66.7 +/- 15.3 years, and mean BMI 30.1 +/- 4.5 kg/m(2)) were used to compare the classification of detected apneas and hypopneas by three methods of respiratory effort evaluation (Pes, RIP belts, and SSP). Signals were analyzed randomly and independently from each other. All recordings were analyzed according to AASM guidelines. Results Using Pes as a reference for apnea characterization, the Cohen kappa (kappa) was 0.93 for SSP and 0.87 for the RIP. The sensitivity/specificity of SSP was 97.0%/96.9% for obstructive, 93.9%/98.3% for central, and 94.9%/97.9% for mixed apneas. The sensitivity/specificity of the RIP was 97.4%/91.9% for obstructive, 87.5%/97.9% for central, and 85.6%/96.6% for mixed apneas. For hypopnea characterization using the Pes as a reference, kappa was 0.92 for SSP and 0.86 for the RIP. The sensitivity/specificity of SSP was 99.7%/97.6% for obstructive and 97.6%/99.7% for central. The sensitivity/specificity of the RIP was 99.8%/81.1% for obstructive and 81.1%/99.8% for central. Conclusions These results confirm the excellent agreement in the detection of respiratory effort between SSP, RIP belts, and Pes signals. Thus, we conclude that apnea and hypopnea characterization in adults with SSP is a reliable method.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30210 - Clinical neurology
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2019
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Sleep and Breathing
ISSN
1520-9512
e-ISSN
—
Volume of the periodical
23
Issue of the periodical within the volume
4
Country of publishing house
US - UNITED STATES
Number of pages
8
Pages from-to
1169-1176
UT code for WoS article
000510403600018