Comparison of different methods of thrombus permeability measurement and impact on recanalization in the INTERRSeCT multinational multicenter prospective cohort study
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00159816%3A_____%2F20%3A00072481" target="_blank" >RIV/00159816:_____/20:00072481 - isvavai.cz</a>
Alternative codes found
RIV/00216224:14110/20:00115996
Result on the web
<a href="https://link.springer.com/article/10.1007%2Fs00234-019-02320-y" target="_blank" >https://link.springer.com/article/10.1007%2Fs00234-019-02320-y</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s00234-019-02320-y" target="_blank" >10.1007/s00234-019-02320-y</a>
Alternative languages
Result language
angličtina
Original language name
Comparison of different methods of thrombus permeability measurement and impact on recanalization in the INTERRSeCT multinational multicenter prospective cohort study
Original language description
Purpose To compare the association of different measures of intracranial thrombus permeability on non-contrast computerized tomography (NCCT) and computed tomography angiography (CTA) with recanalization with or without intravenous alteplase. Methods Patients with anterior circulation occlusion from the INTERRSeCT study were included. Thrombus permeability was measured on non-contrast CT and CTA using the following methods: [1] automated method, mean attenuation increase on co-registered thin (< 2.5 mm) CTA/NCCT; [2] semi-automated method, maximum attenuation increase on non-registered CTA/NCCT (Delta HUmax); [3] manual method, maximum attenuation on CTA (HUmax); and [4] visual method, residual flow grade. Primary outcome was recanalization with intravenous alteplase on the revised AOL scale (2b/3). Regression models were compared using C-statistic, Akaike (AIC), and Bayesian information criterion (BIC). Results Four hundred eighty patients were included in this analysis. Statistical models using methods 2, 3, and 4 were similar in their ability to discriminate recanalizers from non-recanalizers (C-statistic 0.667, 0.683, and 0.634, respectively); method 3 had the least information loss (AIC = 483.8; BIC = 492.2). A HUmax >= 89 measured with method 3 provided optimal sensitivity and specificity in discriminating recanalizers from non-recanalizers [recanalization 55.4% (95%CI 46.2-64.6) when HUmax > 89 vs. 16.8% (95%CI 13.0-20.6) when HUmax <= 89]. In sensitivity analyses restricted to patients with co-registered CTA/NCCT (n = 88), methods 1-4 predicted recanalization similarly (C-statistic 0.641, 0.688, 0.640, 0.648, respectively) with Method 2 having the least information loss (AIC 104.8, BIC 109.8). Conclusion Simple methods that measure thrombus permeability are as reliable as complex image processing methods in discriminating recanalizers from non-recanalizers.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30210 - Clinical neurology
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2020
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Neuroradiology
ISSN
0028-3940
e-ISSN
—
Volume of the periodical
62
Issue of the periodical within the volume
3
Country of publishing house
US - UNITED STATES
Number of pages
6
Pages from-to
—
UT code for WoS article
000495942400003
EID of the result in the Scopus database
—