Association of Stent-Retriever Characteristics in Establishing Successful Reperfusion During Mechanical Thrombectomy Results from the ESCAPE-NA1 Trial
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00159816%3A_____%2F22%3A00077740" target="_blank" >RIV/00159816:_____/22:00077740 - isvavai.cz</a>
Alternative codes found
RIV/00216224:14110/22:00128452
Result on the web
<a href="https://link.springer.com/article/10.1007/s00062-021-01123-0" target="_blank" >https://link.springer.com/article/10.1007/s00062-021-01123-0</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s00062-021-01123-0" target="_blank" >10.1007/s00062-021-01123-0</a>
Alternative languages
Result language
angličtina
Original language name
Association of Stent-Retriever Characteristics in Establishing Successful Reperfusion During Mechanical Thrombectomy Results from the ESCAPE-NA1 Trial
Original language description
Background Successful reperfusion determines the treatment effect of endovascular thrombectomy. We evaluated stent-retriever characteristics and their relation to reperfusion in the ESCAPE-NA1 trial. Methods Independent re-scoring of reperfusion grade for each attempt was conducted. The following characteristics were evaluated: stent-retriever length and diameter, thrombus position within stent-retriever, bypass effect, deployment in the superior or inferior MCA trunk, use of balloon guide catheter and distal access catheter. Primary outcome was successful reperfusion defined as expanded thrombolysis in cerebral infarction (eTICI) 2b-3 per attempt. The secondary outcome was successful reperfusion eTICI 2b-3 after the first attempt. Separate regression models for each stent-retriever characteristic and an exploratory multivariable modeling to test the impact of all characteristics on successful reperfusion were built. Results Of 1105 patients in the trial, 809 with the stent-retriever use (1241 attempts) were included in the primary analysis. The stent-retriever was used as the first-line approach in 751 attempts. A successful attempt was associated with thrombus position within the proximal or middle third of the stent (OR 2.06; 95% CI: 1.24-3.40 and OR 1.92; 95% CI: 1.16-3.15 compared to the distal third respectively) and with bypass effect (OR 1.7; 95% CI: 1.07-2.72). Thrombus position within the proximal or middle third (OR 2.80; 95% CI: 1.47-5.35 and OR 2.05; 95% CI: 1.09-3.84, respectively) was associated with first-pass eTICI 2b-3 reperfusion. In the exploratory analysis accounting for all characteristics, bypass effect was the only independent predictor of eTICI 2b-3 reperfusion (OR 1.95; 95% CI: 1.10-3.46). Conclusion The presence of bypass effect and thrombus positioning within the proximal and middle third of the stent-retriever were strongly associated with successful reperfusion.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30210 - Clinical neurology
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2022
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Clinical Neuroradiology
ISSN
1869-1439
e-ISSN
1869-1447
Volume of the periodical
32
Issue of the periodical within the volume
3
Country of publishing house
US - UNITED STATES
Number of pages
9
Pages from-to
799-807
UT code for WoS article
000739761200001
EID of the result in the Scopus database
—