Intra-septal sensory branch as an alternative to the sural nerve grafting in radial nerve reconstruction: Anatomical and histomorphological study
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00159816%3A_____%2F25%3A00082296" target="_blank" >RIV/00159816:_____/25:00082296 - isvavai.cz</a>
Alternative codes found
RIV/00216224:14110/25:00143742 RIV/00216208:11110/25:10494559 RIV/00216208:11120/25:43928139 RIV/00216208:11130/25:10494559
Result on the web
<a href="https://www.sciencedirect.com/science/article/abs/pii/S1748681525001093" target="_blank" >https://www.sciencedirect.com/science/article/abs/pii/S1748681525001093</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.bjps.2025.02.008" target="_blank" >10.1016/j.bjps.2025.02.008</a>
Alternative languages
Result language
angličtina
Original language name
Intra-septal sensory branch as an alternative to the sural nerve grafting in radial nerve reconstruction: Anatomical and histomorphological study
Original language description
Introduction: Nerve grafting with the sural nerve is a standard treatment method for radial nerve injury that requires another incision at the lateral ankle distal from the injured upper limb. The aim of this study was to investigate the common trunk (CTCB) of the inferior lateral brachial cutaneous nerve (ILBCN) and posterior antebrachial cutaneous nerve (PACN) as a possible donor inside the lateral intermuscular septum. Materials and methods: The arms and legs of 8 formalin-embalmed cadaver specimens were studied. The radial nerve, common trunk of the ILBCN and PACN, and the sural nerve were identified and measured in length and diameter. For histological examination, nerve samples from 6 fresh cadavers were harvested and processed for further axonal counting. Results: The average length of the CTCB was 114.92 +/- 18.9 mm. To match the diameter of the radial nerve at its proximal third, 3 cables of CTCB graft were necessary, which corresponds to a defect length of 3.8 cm. At the level of the distal third, the number of grafts was reduced to 2 with a corresponding defect length of 5.7 cm. The radial nerve contained 15162 +/- 318 axons, and the CTCB comprised 3959 +/- 176 axons. To match the axon count of the recipient nerve, 4 grafts of CTCB were necessary, which corresponded to a defect length of 2.8 cm. Conclusion: CTCB is a consistent and easily dissected cutaneous nerve branch of the radial nerve that can be used for bridging small gaps after neuroma-in-continuity in radial nerve palsy. (c) 2025 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights are reserved, including those for text and data mining, AI training, and similar technologies.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30212 - Surgery
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2025
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Journal of Plastic Reconstructive and Aesthetic Surgery
ISSN
1748-6815
e-ISSN
1878-0539
Volume of the periodical
103
Issue of the periodical within the volume
Apr 2025
Country of publishing house
GB - UNITED KINGDOM
Number of pages
7
Pages from-to
174-180
UT code for WoS article
001432102000001
EID of the result in the Scopus database
—